How are transformer temperature changes assessed?

How are transformer temperature changes assessed?
A transformer is a piece of electrical equipment used to convert electrical energy to different voltage levels and is widely used in power systems. Since significant heat is generated during operation, temperature fluctuations have a major impact on the transformer's performance and lifespan. Therefore, monitoring transformer temperature changes is crucial for the normal operation of the power system. This article details the methods used to assess transformer temperature.

I. Measurement Methods:
1. Transformer Thermometer: Transformers are typically equipped with thermometers to measure the temperature inside the oil tank or on the exterior. These thermometers are usually installed on the top or side of the tank to ensure accurate readings. If the detected temperature exceeds a preset limit, the thermometer can trigger an alarm or initiate an automatic shutdown.
2. Thermistor: Thermistors measure transformer temperature indirectly by detecting changes in electrical resistance; they are usually installed on the transformer windings. As the temperature rises, the resistance value of the thermistor changes; by measuring this change, the transformer's temperature variation can be determined.
3. Infrared Thermometer: Infrared thermometers measure an object's temperature indirectly by detecting the infrared radiation energy emitted from its surface. Transformer exteriors are often enclosed in protective casings, making direct contact impossible. However, infrared thermometers allow for accurate, non-contact measurement of the transformer's surface temperature.
4. Thermal Imaging Camera: Thermal imaging cameras use infrared radiation to rapidly scan and detect the temperature distribution across the transformer's entire exterior surface, displaying the results on a screen. These cameras enable quick and accurate identification of abnormally hot areas and help verify whether cooling components, such as radiators, are functioning correctly.

II. Causes of Temperature Changes:
Transformer temperature changes are primarily caused by the following factors:
1. Load Variation: When the load increases, the transformer generates more heat, causing the temperature to rise accordingly. Conversely, when the load decreases, the transformer's temperature drops.
2. Ambient Temperature: Changes in the external ambient temperature also affect the transformer's temperature. When the ambient temperature rises, the transformer's heat dissipation efficiency decreases, causing its temperature to rise. Conversely, when the ambient temperature drops, heat dissipation improves, and the temperature falls.
3. Insulation aging: Transformer insulation materials are prone to aging over prolonged use. Deterioration of insulation can lead to internal partial short circuits or leakage, generating excess heat and raising the transformer's temperature.
4. Cooling system failure: The cooling system is crucial for maintaining a stable transformer temperature. If the system malfunctions—preventing components like fans or coolers from operating correctly—the transformer's temperature will rise.
5. Failure of electrical components: Malfunctions in components such as switches or protective devices can cause abnormal operation and lead to overheating.

III. How to identify abnormal transformer temperatures:
1. Excessive thermometer readings: Readings from the transformer's thermometer indicate whether the temperature has exceeded the safe operating range. If the reading goes beyond the set limit, the transformer must be inspected for faults.
2. Abnormal sounds or odors: An abnormal rise in temperature may be accompanied by unusual sounds or smells. Sounds such as gushing or loud noises may indicate issues like insulation aging or short circuits.
3. Abnormal surface temperature of the transformer casing: Infrared thermometers or thermal imagers can be used to quickly scan the temperature distribution on the transformer's exterior. If a specific area of ​​the casing is significantly hotter than the surrounding areas, it suggests a potential problem in that section.
4. Overload protection tripping: The overload protector is designed to safeguard the transformer from damage caused by overloading. When the temperature reaches a certain threshold, the protector automatically trips, cutting off the power supply to prevent damage.
5. Abnormal oil quality: Inspecting the transformer oil can reveal signs of overheating or overloading. As the temperature rises, the oil may thin out or exhibit abnormalities such as air bubbles or suspended particles.

IV. Impact of Temperature Changes on Transformers:
1. Increased Power Loss: A rise in transformer temperature increases internal resistance, thereby raising power loss. This increased power loss not only lowers the transformer's overall efficiency but also results in greater electrical energy waste.
2. Accelerated Insulation Aging: Elevated temperatures accelerate the aging of insulation materials, degrading the transformer's insulation performance. Insulation aging can lead to performance decline and increase the risk of faults such as current leakage and short circuits, potentially damaging other equipment.
3. Thermal Stress: As the transformer's temperature rises, differing coefficients of thermal expansion among various components can generate thermal stress, potentially causing internal deformation or damage.
4. Reduced Service Life: Higher temperatures accelerate transformer aging, shortening its service life. Prolonged exposure to excessive temperatures can lead to severe failures—such as short circuits or structural ruptures—and may even trigger fires.

Conclusion: Temperature fluctuations directly affect a transformer's performance and lifespan. Understanding how to assess transformer temperature helps in the timely identification and resolution of temperature anomalies, ensuring normal operation. Temperature status can be evaluated by measuring the temperature, inspecting the equipment's exterior, and monitoring for unusual sounds or odors. Promptly troubleshooting and addressing temperature issues to maintain normal operation is crucial for the safe and reliable functioning of the power system.