SE555P

SE555P


Specifications
SKU
72724
Details

BUY SE555P https://www.utsource.net/itm/p/72724.html
Standard Timer Single -55°C 125°C 8-Pin PDIP Tube
Parameter Symbol Min Typ Max Unit
Supply Voltage Vcc 4.5 - 16 V
Supply Current ICC - 3 10 mA
Trigger Input Vtr 0.1 - 1.1 V
Threshold Input Vth 2/3Vcc - 2/3Vcc V
Control Voltage Vc 0.7 - 18 V
Reset Input Vr 0.7 - 18 V
Output Voltage Vo 0 Vcc-1.5 Vcc-1.5 V
Output Current Io - 200 - μA
Maximum Power Dissipation Pd - 625 - mW
Operating Temperature Ta -55 - 125 °C
Storage Temperature Ts -65 - 150 °C

Instructions for Using the SE555P Timer IC

  1. Power Supply:

    • Connect the supply voltage (Vcc) between pin 8 and ground (pin 1). The SE555P can operate from 4.5V to 16V.
  2. Trigger Input (Pin 2):

    • The trigger input is used to start the timing cycle. It should be pulled low (below 1/3 Vcc) to start the timer.
  3. Threshold Input (Pin 6):

    • The threshold input is used to stop the timing cycle. It should be pulled high (above 2/3 Vcc) to reset the timer.
  4. Control Voltage (Pin 5):

    • This pin can be used to modify the internal reference voltages. If not used, it should be bypassed to ground with a 10nF capacitor.
  5. Reset Input (Pin 4):

    • The reset input can be used to disable the timer. It should be held high (Vcc) to enable the timer. Pulling it low will reset the timer.
  6. Output (Pin 3):

    • The output pin provides the timing signal. It can drive loads up to 200μA. For higher current loads, use a transistor or other driver circuit.
  7. Discharge (Pin 7):

    • This pin is used to discharge the external capacitor during the timing cycle. It is internally connected to the output and ground.
  8. Ground (Pin 1):

    • Connect this pin to the ground of your power supply.
  9. Capacitor and Resistor Selection:

    • For monostable mode, connect a resistor between pin 7 and Vcc, and a capacitor between pin 6 and ground.
    • For astable mode, connect a resistor between pin 7 and Vcc, and another resistor between pin 7 and pin 6. Connect a capacitor between pin 6 and ground.
  10. Thermal Considerations:

    • Ensure that the device is not operated beyond its maximum power dissipation. Use a heat sink if necessary.
  11. Operating and Storage Temperature:

    • The SE555P can operate from -55°C to 125°C and can be stored from -65°C to 150°C.
  12. Handling Precautions:

    • The SE555P is sensitive to static electricity. Handle the device with care and use proper ESD protection.

By following these instructions, you can effectively use the SE555P timer IC in various applications such as oscillators, timers, and pulse generators.

(For reference only)

View more about SE555P on main site