Details
BUY CD4520BE https://www.utsource.net/itm/p/107101.html
Dual Up Counters
Below is the parameter table and instructions for the CD4520BE dual 8-bit binary counter.
Parameter Table
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | VDD | 3 | - | 18 | V |
Input Voltage (High) | VIH | - | - | VDD - 1.5 | V |
Input Voltage (Low) | VIL | 0 | - | VDD - 3.5 | V |
Output Voltage (High) | VOH | VDD - 1.5 | - | VDD - 0.5 | V |
Output Voltage (Low) | VOL | 0 | - | 0.5 | V |
Propagation Delay Time | tpd | - | 70 | 150 | ns |
Power Dissipation | PD | - | - | 100 | mW |
Operating Temperature Range | TA | -40 | - | 85 | 掳C |
Storage Temperature Range | TSTG | -65 | - | 150 | 掳C |
Instructions
Power Supply:
- Connect VDD to the positive supply voltage (3V to 18V).
- Connect VSS to ground (0V).
Clock Input:
- Apply the clock signal to the CLK input of each counter.
- The counters will increment on the rising edge of the clock signal.
Reset Input:
- Connect the reset input (RST) to a logic high level to reset the counter to zero.
- Connect RST to ground to allow normal counting operation.
Enable Inputs:
- Connect the enable inputs (ENP and ENT) to logic high to enable counting.
- Connect ENP or ENT to ground to disable counting.
Output:
- The outputs (Q0 to Q7) represent the binary count from 0 to 255 (for each 8-bit counter).
- The outputs can be used to drive other logic circuits or connected to external devices.
Cascade Operation:
- To cascade multiple CD4520BE counters, connect the carry-out (CO) of one counter to the clock input (CLK) of the next counter.
- This allows for counting beyond 255 by combining multiple 8-bit counters.
Power-On Reset:
- It is recommended to use a power-on reset circuit to ensure that the counters start from zero when power is applied.
- A simple RC circuit can be used to generate a reset pulse at power-up.
Decoupling Capacitors:
- Place a 0.1渭F ceramic capacitor between VDD and VSS close to the device to reduce noise and improve stability.
Handling Precautions:
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
- Use proper grounding and handling techniques when working with the device.
Storage:
- Store the device in a dry environment to prevent moisture damage.
- Follow the storage temperature range specified in the parameter table.
By following these instructions, you can effectively use the CD4520BE dual 8-bit binary counter in your digital circuits.
(For reference only)View more about CD4520BE on main site