SKM100GAR123D

SKM100GAR123D

Category: Modules

Specifications
SKU
199892
Details

BUY SKM100GAR123D https://www.utsource.net/itm/p/199892.html
SEMITRANS IGBT Modules New Range
Parameter Description Value Unit
Part Number Component Identifier SKM100GAR123D -
Type Device Type IGBT Module -
Package Package Type SEMITOP M -
Collector-Emitter Voltage (Vce) Maximum Collector-Emitter Voltage 1200 V
Collector Current (Ic) Continuous Collector Current at Tc = 25°C 100 A
Collector Current (Ic) Continuous Collector Current at Tc = 100°C 70 A
Pulse Collector Current (Icm) Non-Repetitive Peak Collector Current (10 ms, 1 cycle) 200 A
Gate-Emitter Voltage (Vge) Maximum Gate-Emitter Voltage ±20 V
Power Dissipation (Ptot) Total Power Dissipation at Tc = 25°C 1400 W
Power Dissipation (Ptot) Total Power Dissipation at Tc = 100°C 980 W
Thermal Resistance (Rth(j-c)) Thermal Resistance, Junction to Case 0.16 K/W
Operating Temperature Range (Tj) Junction Operating Temperature Range -40 to 150 °C
Storage Temperature Range (Tstg) Storage Temperature Range -40 to 150 °C
Humidity Relative Humidity 20% to 90% (non-condensing) %

Instructions for Use

  1. Handling and Storage:

    • Store the module in a dry, cool place with relative humidity between 20% and 90%.
    • Avoid exposure to extreme temperatures and direct sunlight.
    • Handle the module with care to avoid mechanical damage.
  2. Mounting:

    • Ensure the mounting surface is flat and clean.
    • Apply thermal grease or a thermal pad to improve heat dissipation.
    • Tighten the mounting screws to the recommended torque (refer to the datasheet for specific values).
  3. Electrical Connections:

    • Connect the collector, emitter, and gate terminals according to the circuit diagram.
    • Use high-quality, low-inductance wires for connections.
    • Ensure all connections are secure and free from corrosion.
  4. Operation:

    • Operate the module within the specified voltage and current limits.
    • Monitor the junction temperature to ensure it does not exceed the maximum operating temperature.
    • Use appropriate cooling solutions (e.g., heatsinks, fans) to maintain optimal operating conditions.
  5. Testing:

    • Perform initial testing under controlled conditions to verify proper operation.
    • Use a suitable test setup to measure key parameters such as Vce, Ic, and Vge.
    • Refer to the datasheet for detailed testing procedures and safety guidelines.
  6. Safety:

    • Follow all safety guidelines and precautions when handling high-voltage and high-current circuits.
    • Use protective equipment such as gloves and safety glasses.
    • Ensure the module is properly insulated and grounded to prevent electrical shock.
(For reference only)

View more about SKM100GAR123D on main site