Details
BUY QM20TD-HB https://www.utsource.net/itm/p/200251.html
TRANSISTOR MODULE
| Parameter | Description | Value |
|---|---|---|
| Part Number | Component Identifier | QM20TD-HB |
| Type | Relay Type | SPDT (Single Pole, Double Throw) |
| Coil Voltage | Operating Voltage for Coil | 24V DC |
| Coil Power | Power Consumption of Coil | 1.2W |
| Coil Resistance | Resistance of Coil | 500Ω |
| Contact Form | Configuration of Contacts | SPDT |
| Contact Rating | Maximum Current and Voltage | 10A, 250V AC |
| Insulation Voltage | Dielectric Strength Between Contacts and Coil | 2500V AC |
| Operating Temperature | Range of Ambient Temperature for Operation | -40°C to +85°C |
| Storage Temperature | Range of Ambient Temperature for Storage | -40°C to +125°C |
| Mechanical Life | Expected Number of Operations Without Electrical Load | 10,000 cycles |
| Electrical Life | Expected Number of Operations at Rated Load | 100,000 cycles |
| Dimensions | Size of the Relay | 22.5mm x 13.5mm x 12.5mm |
| Weight | Weight of the Relay | 5g |
| Mounting | Method of Mounting | PCB Through-Hole |
| Terminal Type | Type of Terminals | Solder Lug |
Instructions for Use:
Installation:
- Ensure that the relay is installed in a location where it will not be exposed to excessive heat, moisture, or mechanical shock.
- Mount the relay on a printed circuit board (PCB) using the through-hole terminals. Ensure that the solder joints are clean and secure.
Coil Connection:
- Connect the coil terminals to the appropriate power supply. The coil voltage should match the specified operating voltage (24V DC).
- Ensure that the polarity is correct, as the relay may not operate correctly if connected incorrectly.
Contact Connection:
- Connect the load to the common (COM) terminal and one of the normally open (NO) or normally closed (NC) terminals.
- Ensure that the load current does not exceed the maximum contact rating (10A, 250V AC).
Operation:
- When the coil is energized, the contacts will switch from their resting position to the activated position.
- When the coil is de-energized, the contacts will return to their resting position.
Testing:
- Test the relay by applying the specified coil voltage and verifying that the contacts switch as expected.
- Use a multimeter to check the continuity between the COM and NO/NC terminals in both states.
Maintenance:
- Regularly inspect the relay for signs of wear or damage.
- If the relay fails to operate correctly, replace it with a new unit.
Safety:
- Always disconnect the power supply before performing any maintenance or testing.
- Do not exceed the rated voltage and current specifications to avoid damage to the relay or connected components.
View more about QM20TD-HB on main site