Details
BUY TT105N14LOF https://www.utsource.net/itm/p/281468.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | V_IN | 4.5 | - | 14 | V | Operating input voltage range |
Output Voltage | V_OUT | - | 5 | - | V | Regulated output voltage |
Quiescent Current | I_Q | - | 60 | - | μA | Typical quiescent current |
Dropout Voltage | V_DROPOUT | - | 70 | - | mV | Dropout voltage at full load |
Load Regulation | - | - | 0.2 | - | % | Change in output voltage over load |
Line Regulation | - | - | 0.05 | - | %/V | Change in output voltage over line |
Maximum Output Current | I_OUT | - | 500 | - | mA | Continuous output current |
Operating Temperature | T_OP | -40 | - | 85 | °C | Operating temperature range |
Instructions for TT105N14LOF:
Installation:
- Ensure the input voltage is within the specified range (4.5V to 14V).
- Connect the input pin to the power supply and the output pin to the load.
- Ground the GND pin properly to ensure stable operation.
Capacitors:
- Place a 1μF ceramic capacitor between the input and ground close to the device for stability.
- Optionally, place a 1μF ceramic capacitor between the output and ground for improved transient response.
Thermal Considerations:
- The device should be mounted on a PCB with adequate copper area for heat dissipation.
- If operating near the maximum temperature or current, consider additional cooling methods like heatsinks.
Handling:
- Handle the component carefully to avoid damage from electrostatic discharge (ESD).
- Follow standard ESD protection guidelines during assembly and handling.
Testing:
- After installation, verify the output voltage is stable at 5V under varying load conditions.
- Check the quiescent current to ensure it remains within the typical value of 60μA.
Troubleshooting:
- If the output voltage is unstable, check the input voltage and capacitors.
- Ensure all connections are secure and free from shorts or opens.
View more about TT105N14LOF on main site