MG15H1AL1

MG15H1AL1

Category: Modules

Specifications
SKU
281551
Details

BUY MG15H1AL1 https://www.utsource.net/itm/p/281551.html
Catalog Scans - Shortform Datasheet
Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 4.5 5 5.5 V Operating voltage range
Supply Current Icc - 20 - mA Typical supply current
Output Current Iout - 100 - mA Maximum output current per channel
Output Voltage Drop Vsat - 0.3 - V Saturation voltage (Vce(sat)) at Iout = 100mA
Input Voltage (High) VIH 2 - 5.5 V Minimum input voltage for logic high
Input Voltage (Low) VIL 0 - 0.8 V Maximum input voltage for logic low
Input Current (High) IIH - 1 - μA Input current at VIH = 5V
Input Current (Low) IIL - 1 - μA Input current at VIL = 0V
Operating Temperature Topr -40 - 85 °C Operating temperature range
Storage Temperature Tstg -65 - 150 °C Storage temperature range

Instructions for Using MG15H1AL1

  1. Power Supply:

    • Ensure the supply voltage is within the range of 4.5V to 5.5V.
    • Connect the Vcc pin to the positive terminal of the power supply and GND to the ground.
  2. Input Signals:

    • Apply logic high (VIH ≥ 2V) to activate the output.
    • Apply logic low (VIL ≤ 0.8V) to deactivate the output.
    • Ensure input currents do not exceed 1μA for both high and low states.
  3. Output Configuration:

    • The output can source up to 100mA of current.
    • The output voltage drop (Vsat) should be considered when designing the load circuit, as it is typically around 0.3V at 100mA.
  4. Thermal Management:

    • Operate the device within the temperature range of -40°C to 85°C.
    • Store the device in an environment between -65°C and 150°C.
  5. Handling and Storage:

    • Handle the device with care to avoid static damage.
    • Store the device in a dry, cool place to prevent moisture damage.
  6. Schematic Integration:

    • Connect the output pins to the load, ensuring the load does not exceed the maximum current rating.
    • Use appropriate decoupling capacitors near the power supply pins to stabilize the supply voltage.
  7. Testing:

    • Test the device under typical operating conditions to ensure proper functionality.
    • Verify that the output behaves correctly for both high and low input signals.
  8. Safety:

    • Follow all safety guidelines and regulations when handling and using the device.
    • Do not exceed the maximum ratings specified in the parameter table to avoid damage to the device.
(For reference only)