Details
BUY SKM300GAR123D https://www.utsource.net/itm/p/327388.html
IGBT Modules
Parameter | Description | Value | Unit |
---|---|---|---|
Type | Device Type | IGBT Module | - |
Part Number | Product Code | SKM300GAR123D | - |
Collector-Emitter Voltage (Vce) | Maximum Collector-Emitter Voltage | 1200 | V |
Collector Current (Ic) | Continuous Collector Current | 300 | A |
Collector-Emitter Saturation Voltage (Vce(sat)) | Collector-Emitter Saturation Voltage at Ic = 150A, Tc = 25°C | 2.0 | V |
Gate-Emitter Voltage (Vge) | Maximum Gate-Emitter Voltage | ±20 | V |
Turn-On Time (ton) | Turn-On Time | 0.7 | μs |
Turn-Off Time (toff) | Turn-Off Time | 1.5 | μs |
Thermal Resistance (Rth(j-c)) | Junction to Case Thermal Resistance | 0.17 | K/W |
Operating Temperature Range (Tj) | Junction Temperature Range | -40 to 150 | °C |
Storage Temperature Range (Tstg) | Storage Temperature Range | -40 to 150 | °C |
Case Type | Package Type | Industry Standard Module | - |
Weight | Weight of the Module | 1.2 | kg |
Instructions for Use:
Mounting and Handling:
- Ensure that the module is handled with care to avoid mechanical damage.
- Use appropriate mounting hardware to secure the module to a heatsink or cooling system.
- Apply thermal grease or a thermal pad between the module and the heatsink to ensure good thermal contact.
Electrical Connections:
- Connect the collector (C), emitter (E), and gate (G) terminals according to the circuit diagram.
- Ensure that all connections are secure and free from corrosion.
- Use insulated tools and equipment to prevent short circuits.
Power Supply:
- Ensure that the power supply voltage does not exceed the maximum ratings specified.
- Use a suitable gate driver circuit to control the IGBT.
Thermal Management:
- Monitor the junction temperature (Tj) to ensure it remains within the operating range.
- Use a heatsink or active cooling system to dissipate heat effectively.
Safety Precautions:
- Follow all safety guidelines and regulations when handling high-voltage and high-current circuits.
- Use protective equipment such as gloves and safety glasses.
Testing and Troubleshooting:
- Test the module in a controlled environment before integrating it into the final application.
- If the module fails to operate correctly, check for proper connections, correct voltage levels, and thermal management.
For detailed technical specifications and additional information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about SKM300GAR123D on main site