Details
BUY MAX516ACNG https://www.utsource.net/itm/p/350644.html
Quad Comparator with Programmable Threshold
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating | 4.75 | - | 5.25 | V |
| Output Voltage Range | VOUT | - | 0 | - | VCC | V |
| Output Current | IOUT | Continuous | - | 10 | - | mA |
| Power Dissipation | PD | Continuous | - | - | 150 | mW |
| Operating Temperature | TOP | Commercial | 0 | - | 70 | °C |
| Storage Temperature | TSTG | - | -40 | - | 85 | °C |
| Input Resistance | RIN | - | - | 10 | - | kΩ |
| Output Resistance | ROUT | - | - | 1 | - | Ω |
| Line Regulation | - | 1% change in VCC | - | 0.01 | - | % |
| Load Regulation | - | 10 mA load change | - | 0.01 | - | % |
| Settling Time (10% to 90%) | tS | 10 mA load | - | 10 | - | μs |
Instructions for Use:
Power Supply:
- Ensure the supply voltage is within the specified range (4.75V to 5.25V).
- Use a stable power source to avoid fluctuations that can affect performance.
Output Configuration:
- The output voltage can be set using external resistors or through digital control, depending on the specific model.
- Ensure the load current does not exceed 10 mA continuously.
Thermal Management:
- The device can dissipate up to 150 mW of power continuously.
- For higher power dissipation, consider adding a heat sink or ensuring adequate airflow.
Temperature Range:
- Operate the device within the commercial temperature range (0°C to 70°C) for optimal performance.
- Store the device in a temperature range between -40°C and 85°C.
Input and Output Resistance:
- The input resistance is typically 10 kΩ, and the output resistance is typically 1 Ω.
- These values should be considered when designing the circuit to ensure proper signal integrity.
Regulation:
- The line regulation is 0.01%, meaning the output voltage will change by only 0.01% for a 1% change in supply voltage.
- The load regulation is also 0.01%, indicating the output voltage will change by only 0.01% for a 10 mA load change.
Settling Time:
- The settling time from 10% to 90% of the final output voltage is typically 10 μs under a 10 mA load.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store in a dry, cool place to prevent moisture damage.
For more detailed information, refer to the datasheet provided by Maxim Integrated.