Quad Comparator with Programmable Threshold
Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 4.75 - 5.25 V
Output Voltage Range VOUT - 0 - VCC V
Output Current IOUT Continuous - 10 - mA
Power Dissipation PD Continuous - - 150 mW
Operating Temperature TOP Commercial 0 - 70 °C
Storage Temperature TSTG - -40 - 85 °C
Input Resistance RIN - - 10 -
Output Resistance ROUT - - 1 - Ω
Line Regulation - 1% change in VCC - 0.01 - %
Load Regulation - 10 mA load change - 0.01 - %
Settling Time (10% to 90%) tS 10 mA load - 10 - μs

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage is within the specified range (4.75V to 5.25V).
    • Use a stable power source to avoid fluctuations that can affect performance.
  2. Output Configuration:

    • The output voltage can be set using external resistors or through digital control, depending on the specific model.
    • Ensure the load current does not exceed 10 mA continuously.
  3. Thermal Management:

    • The device can dissipate up to 150 mW of power continuously.
    • For higher power dissipation, consider adding a heat sink or ensuring adequate airflow.
  4. Temperature Range:

    • Operate the device within the commercial temperature range (0°C to 70°C) for optimal performance.
    • Store the device in a temperature range between -40°C and 85°C.
  5. Input and Output Resistance:

    • The input resistance is typically 10 kΩ, and the output resistance is typically 1 Ω.
    • These values should be considered when designing the circuit to ensure proper signal integrity.
  6. Regulation:

    • The line regulation is 0.01%, meaning the output voltage will change by only 0.01% for a 1% change in supply voltage.
    • The load regulation is also 0.01%, indicating the output voltage will change by only 0.01% for a 10 mA load change.
  7. Settling Time:

    • The settling time from 10% to 90% of the final output voltage is typically 10 μs under a 10 mA load.
  8. Handling and Storage:

    • Handle the device with care to avoid static damage.
    • Store in a dry, cool place to prevent moisture damage.

For more detailed information, refer to the datasheet provided by Maxim Integrated.