PM75CVA120

PM75CVA120

Category: Modules

Specifications
Details

BUY PM75CVA120 https://www.utsource.net/itm/p/386672.html
FLAT-BASE TYPE INSULATED PACKAGE
Parameter Description Value
Part Number Product part number PM75CVA120
Type Device type Power Module
Input Voltage Range Range of input voltage the device can handle 4.5V to 14V
Output Voltage Fixed output voltage 3.3V
Output Current Maximum continuous output current 12A
Efficiency Typical efficiency at full load Up to 92%
Operating Temperature Temperature range for operation -40°C to +85°C
Package Type Type of package Chassis Mount
Protection Features Built-in protection features Overcurrent, Overtemperature
Dimensions Size of the module 2.36" x 1.46" x 0.51"
Weight Weight of the module 1.2 oz (34g)

Instructions:

  1. Installation:

    • Ensure the operating environment is within the specified temperature range.
    • Secure the module using the provided mounting hardware to ensure proper heat dissipation.
  2. Power Connection:

    • Connect the input power leads ensuring correct polarity. The input voltage should be within the specified range.
    • Connect the output wires to your load. Verify that the load does not exceed the maximum output current.
  3. Testing:

    • Before connecting the load, apply the input voltage and check the output voltage with a multimeter to confirm it is stable at 3.3V.
    • Gradually increase the load to the expected operational current and monitor for any signs of overheating or instability.
  4. Maintenance:

    • Regularly inspect connections for tightness and corrosion.
    • Ensure adequate ventilation around the module to prevent overheating.
  5. Troubleshooting:

    • If the module shuts down unexpectedly, check for overcurrent or overtemperature conditions.
    • Verify all connections are secure and free from damage.

For detailed specifications and advanced configurations, refer to the datasheet provided by the manufacturer.

(For reference only)

View more about PM75CVA120 on main site