Details
BUY MG200Q2YS50 https://www.utsource.net/itm/p/387154.html
Vces (volts) = 1200 ;; Ic (amps) = 200 ;; Vce (sat) Max = 3.6 ;; Ton (usec) = 0.2 ;; Toff (usec) = 0.6
Below is the parameter table and instructions for the MG200Q2YS50.
Parameter Table
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | 5.0 | 5.5 | V |
Operating Temperature | Ta | -40 | - | 85 | °C |
Storage Temperature | Tstg | -55 | - | 125 | °C |
Output Current (Per Phase) | Iout | - | 200 | - | mA |
PWM Frequency | fPWM | - | 20 | - | kHz |
Dead Time | tD | - | 0.5 | - | μs |
Standby Current | Isb | - | 10 | - | μA |
Logic Input Voltage (High) | VIH | 3.5 | - | 5.5 | V |
Logic Input Voltage (Low) | VIL | 0 | - | 1.5 | V |
Instructions
Power Supply Connection:
- Connect the Vcc pin to a stable 5V power supply.
- Ensure the GND pin is connected to the common ground.
Logic Input:
- Apply logic high (VIH) to the control pins to activate the corresponding outputs.
- Apply logic low (VIL) to deactivate the outputs.
- Ensure the input voltages are within the specified range to avoid damage.
Output Configuration:
- The device can drive up to 200mA per phase.
- Do not exceed the maximum output current to prevent overheating and potential damage.
PWM Control:
- Use a PWM signal with a frequency of 20kHz for optimal performance.
- Adjust the duty cycle to control the output power.
Dead Time:
- A dead time of 0.5μs is automatically inserted between the switching of complementary outputs to prevent shoot-through.
Thermal Management:
- Ensure adequate heat dissipation if operating at high currents or temperatures.
- Use a heatsink if necessary, especially in high-power applications.
Standby Mode:
- To enter standby mode, set all control inputs to low.
- The device will draw minimal current (Isb) in this state.
Storage and Handling:
- Store the device in a dry environment within the specified temperature range.
- Handle with care to avoid static discharge, which can damage the internal circuits.
Testing and Verification:
- Before integrating into a final design, test the device under typical operating conditions to ensure it meets the required specifications.
Compliance:
- Ensure that the device is used in compliance with all relevant safety and regulatory standards.
By following these instructions, you can ensure reliable and efficient operation of the MG200Q2YS50.
(For reference only)View more about MG200Q2YS50 on main site