| Parameter | Description | Value |
|---|---|---|
| Package Type | Type of package | SOP-8 |
| Operating Voltage (Vcc) | Supply voltage range | 2.7V to 5.5V |
| Output Current (Iout) | Maximum output current per channel | 30mA |
| Operating Temperature (Tamb) | Ambient temperature range | -40°C to +85°C |
| Storage Temperature (Tstg) | Storage temperature range | -65°C to +150°C |
| Input Voltage Range (Vin) | Input voltage range for logic levels | 0V to Vcc |
| Propagation Delay (tPD) | Time delay from input to output | 10ns (typical) at Vcc = 5V |
| Power Dissipation (Pd) | Maximum power dissipation | 360mW |
| ESD Protection | Electrostatic discharge protection | HBM: ±2kV, MM: ±200V |
| Quiescent Current (Iq) | Current consumption when idle | 1μA (typical) |
| Output Type | Type of output stage | Push-Pull |
Instructions for Use
Power Supply Connection:
- Connect the Vcc pin to the positive supply voltage within the specified range (2.7V to 5.5V).
- Connect the GND pin to the system ground.
Input Signal:
- Apply logic level signals to the input pins. The input voltage should be within the range of 0V to Vcc.
- Ensure that the input signals are clean and stable to avoid unintended switching.
Output Load:
- Connect the load to the output pins. The maximum current per channel is 30mA.
- Ensure that the load resistance is appropriate to limit the current to within the specified range.
Decoupling Capacitors:
- Place a 0.1μF ceramic capacitor between Vcc and GND as close to the device as possible to filter out noise and provide stable operation.
Thermal Management:
- Ensure adequate heat dissipation if the device is operating near its maximum power dissipation. This can be achieved by using a heatsink or ensuring good airflow around the device.
ESD Handling:
- Handle the device with ESD precautions to avoid damage. Use grounded wrist straps and static-safe work surfaces.
Testing and Debugging:
- Use a multimeter to verify the supply voltage and output voltages.
- Use an oscilloscope to check the propagation delay and signal integrity.
Storage and Handling:
- Store the device in a dry, cool place within the specified storage temperature range.
- Avoid exposing the device to extreme temperatures or humidity.
Compliance and Standards:
- Ensure that the device is used in compliance with relevant safety and regulatory standards.
For more detailed information, refer to the datasheet provided by the manufacturer.