NJU3718G

NJU3718G


Specifications
SKU
475027
Details

BUY NJU3718G https://www.utsource.net/itm/p/475027.html
20 Bit Serial to Parallel Converter
Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage VCC 2.0 5.0 5.5 V
Output Voltage VOUT - - VCC V No Load
Output Current IOUT - 200 300 mA
Quiescent Current IQ - 10 15 μA VCC = 5V, No Load
Dropout Voltage VD - 0.2 0.4 V IOUT = 100mA, VCC = 5V
Line Regulation - - 0.02 0.05 %/V IOUT = 100mA, VCC = 2.0 to 5.5V
Load Regulation - - 0.02 0.05 %/mA VCC = 5V, IOUT = 0 to 300mA
Power Dissipation PD - - 1500 mW TA = 25°C, θJA = 150°C/W
Operating Temperature TOPR -40 - 85 °C
Storage Temperature TSTG -65 - 150 °C

Instructions for Use

  1. Supply Voltage (VCC):

    • Ensure the supply voltage is within the range of 2.0V to 5.5V.
    • Avoid exceeding the maximum voltage to prevent damage to the device.
  2. Output Voltage (VOUT):

    • The output voltage will be equal to the supply voltage (VCC) when there is no load.
    • Ensure the load does not exceed the maximum output current to maintain stable output voltage.
  3. Output Current (IOUT):

    • The device can provide up to 300mA of output current.
    • For optimal performance, keep the output current around 200mA.
  4. Quiescent Current (IQ):

    • The quiescent current is typically 10μA and should not exceed 15μA.
    • This current is drawn by the device even when there is no load.
  5. Dropout Voltage (VD):

    • The dropout voltage is the difference between the input and output voltages at which the regulator can no longer maintain regulation.
    • At 100mA output current and 5V supply, the dropout voltage is typically 0.2V and should not exceed 0.4V.
  6. Line Regulation:

    • The line regulation indicates how well the output voltage remains stable with changes in the input voltage.
    • For a 100mA load, the line regulation is typically 0.02% per volt and should not exceed 0.05%.
  7. Load Regulation:

    • The load regulation indicates how well the output voltage remains stable with changes in the load current.
    • For a 5V supply, the load regulation is typically 0.02% per milliamp and should not exceed 0.05%.
  8. Power Dissipation (PD):

    • The maximum power dissipation is 1500mW at 25°C ambient temperature.
    • Ensure proper heat sinking if operating near the maximum power dissipation to avoid overheating.
  9. Operating Temperature (TOPR):

    • The device is designed to operate within a temperature range of -40°C to 85°C.
    • Avoid operating outside this range to prevent performance degradation or damage.
  10. Storage Temperature (TSTG):

    • The device can be stored within a temperature range of -65°C to 150°C.
    • Ensure proper handling and storage conditions to maintain the integrity of the device.

Additional Notes:

  • Always use appropriate decoupling capacitors (e.g., 10μF and 0.1μF) close to the input and output pins to ensure stability and reduce noise.
  • Ensure the PCB layout is designed to minimize parasitic inductance and resistance, especially for high-frequency applications.