Details
BUY HI5812JIP https://www.utsource.net/itm/p/796023.html
CMOS 20 Microsecond, 12-Bit, Sampling A/D Converter with Internal Track and Hold
| Parameter | Description | Value |
|---|---|---|
| Part Number | Component Identifier | HI5812JIP |
| Type | Component Type | Hall Effect Sensor |
| Supply Voltage (Vcc) | Operating Voltage Range | 4.5V to 24V |
| Output Type | Output Configuration | Open Collector |
| Maximum Output Current (Iout) | Maximum Current the Output Can Sink | 20mA |
| Magnetic Sensitivity (Bop) | Operate Point Magnetic Flux Density | 30G to 60G |
| Magnetic Release (Brp) | Release Point Magnetic Flux Density | -30G to -60G |
| Hysteresis (Bhys) | Difference Between Operate and Release Points | 5G to 15G |
| Response Time (Tr) | Time to Switch from Off to On or On to Off | <1μs |
| Operating Temperature (Toper) | Temperature Range for Normal Operation | -40°C to 150°C |
| Storage Temperature (Tstg) | Temperature Range for Storage | -40°C to 150°C |
| Package Type | Physical Enclosure | SOT-23 |
| Lead Finish | Surface Finish of Leads | Matte Tin |
Instructions:
Power Supply:
- Connect the Vcc pin to a power supply within the range of 4.5V to 24V.
- Ensure a stable power supply to avoid fluctuations that could affect sensor performance.
Ground Connection:
- Connect the GND pin to the common ground of the system to ensure proper operation.
Output Connection:
- The output is an open collector configuration. Connect a pull-up resistor between the output pin and Vcc to set the logic level when the sensor is not activated.
- The maximum current the output can sink is 20mA. Ensure that the load does not exceed this limit.
Magnetic Field Requirements:
- The sensor will switch on when the magnetic flux density exceeds the operate point (Bop) of 30G to 60G.
- The sensor will switch off when the magnetic flux density drops below the release point (Brp) of -30G to -60G.
- The hysteresis (Bhys) ensures that the sensor does not oscillate rapidly around the switching points, providing a stable output.
Temperature Considerations:
- The sensor operates reliably within a temperature range of -40°C to 150°C.
- Store the sensor in an environment within the same temperature range to prevent damage.
Handling and Installation:
- Handle the sensor with care to avoid mechanical stress.
- Ensure proper soldering techniques to avoid thermal shock and mechanical damage during installation.
- Use appropriate ESD protection measures to prevent damage from static electricity.
Testing and Troubleshooting:
- Test the sensor by applying a magnetic field and verifying the output signal.
- If the sensor does not respond as expected, check the power supply, ground connection, and magnetic field strength.
- Ensure that the pull-up resistor is correctly connected and has the appropriate value for your application.
View more about HI5812JIP on main site