Details
BUY A3966SA https://www.utsource.net/itm/p/818187.html
DUAL FULL-BRIDGE PWM MOTOR DRIVER
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage | VCC | 8 | - | 50 | V |
| Standby Current | ISB | - | 10 | - | μA |
| Operating Temperature Range | Toper | -40 | - | 125 | °C |
| Storage Temperature Range | Tstg | -65 | - | 150 | °C |
| Maximum Output Current | IOUT | - | 700 | - | mA |
| Thermal Shutdown Threshold | TSD | - | 150 | - | °C |
| Under-Voltage Lockout | UVLO | 4.5 | - | - | V |
| Overcurrent Protection | OCP | - | 1.5 | - | A |
| Phase-Locked Loop Bandwidth | PLLBW | - | 200 | - | kHz |
Instructions for A3966SA
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 8V to 50V.
- Use appropriate decoupling capacitors (e.g., 10μF and 0.1μF) close to the VCC pin to stabilize the power supply.
Thermal Management:
- The device has a thermal shutdown threshold of 150°C. Ensure adequate heat dissipation by using a heatsink or mounting the device on a large copper area.
Current Limiting:
- The maximum output current (IOUT) is 700mA. Use the overcurrent protection (OCP) feature to prevent damage from excessive current draw.
Under-Voltage Lockout:
- The under-voltage lockout (UVLO) activates when the supply voltage drops below 4.5V. Ensure the supply voltage remains above this threshold to maintain operation.
Temperature Range:
- The operating temperature range is from -40°C to 125°C. Store the device within the storage temperature range of -65°C to 150°C.
Phase-Locked Loop:
- The phase-locked loop (PLL) bandwidth is 200kHz. This helps in maintaining synchronization with external signals.
Standby Mode:
- The standby current (ISB) is typically 10μA. Use the standby mode to reduce power consumption when the device is not in use.
Application Notes:
- Refer to the datasheet for detailed application notes and circuit diagrams to ensure proper integration into your design.
View more about A3966SA on main site