| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | Continuous Operation | 5.5 | - | 45 | V |
| Quiescent Current | Iq | No Load, Vcc = 5V | - | 150 | - | mA |
| Peak Output Current | Iout (peak) | Pulse Width Modulation, Vcc = 45V | - | - | 3 | A |
| Continuous Output Current | Iout (cont) | Continuous Operation, Vcc = 45V | - | - | 2 | A |
| Thermal Shutdown Temperature | TSD | - | 160 | - | 170 | °C |
| Operating Junction Temperature | TJ(op) | - | -40 | - | 150 | °C |
| Storage Temperature | TSTG | - | -65 | - | 150 | °C |
| Power Dissipation | PD | θJA = 62°C/W | - | - | 1.5 | W |
| Input High Voltage | VIH | - | 2.0 | - | 5.5 | V |
| Input Low Voltage | VIL | - | 0.8 | - | 2.0 | V |
| Input Current | IIN | Vcc = 5V | - | 10 | - | μA |
| Short-Circuit Protection | - | Active, Self-Limiting | - | - | - | - |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 5.5V to 45V.
- Use a power supply capable of providing sufficient current to meet the peak and continuous output current requirements.
Current Limiting:
- The LMD18245T has built-in current limiting to protect against overcurrent conditions.
- For continuous operation, do not exceed 2A of output current.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it does not exceed 150°C.
- Use appropriate heatsinking to manage power dissipation, especially when operating at higher currents or in high ambient temperatures.
Input Signals:
- Apply input signals with voltages between 0.8V and 5.5V to control the motor driver.
- Ensure the input current does not exceed 10μA to avoid damage to the input pins.
Short-Circuit Protection:
- The device includes short-circuit protection, which will limit the current and prevent damage in case of a short circuit.
- If a short circuit occurs, the device will automatically shut down and reset once the fault is cleared.
Thermal Shutdown:
- The device will shut down if the internal temperature exceeds 160°C to 170°C.
- Allow the device to cool before resuming operation.
Storage and Handling:
- Store the device in a temperature range of -65°C to 150°C.
- Handle with care to avoid static discharge, which can damage the device.
Mounting:
- Mount the device on a PCB with adequate thermal management to ensure reliable operation.
- Follow recommended PCB layout guidelines to minimize parasitic inductance and capacitance.