Details
BUY M27C1001-70B1 https://www.utsource.net/itm/p/861991.html
1 MBIT 128KB X8 UV EPROM AND OTP EPROM
Parameter | Description | Value |
---|---|---|
Device Type | Flash Memory | - |
Manufacturer | Macronix | - |
Part Number | M27C1001-70B1 | - |
Memory Size | 1 Mbit (128 K x 8) | - |
Vcc Supply Voltage | Operating Voltage | 4.5V to 5.5V |
Vpp Programming Voltage | Programming Voltage | 12.0V ± 0.5V |
Access Time | Read Access Time | 70ns (max) |
Data Retention | Data Retention | 10 years (typical) |
Write Cycle Time | Write Cycle Time | 4ms (max) |
Erase Cycle Time | Erase Cycle Time | 1s (max) |
Operating Temperature | Industrial Temperature Range | -40°C to +85°C |
Storage Temperature | Storage Temperature | -65°C to +150°C |
Package Type | Package | DIP-28, PLCC-32 |
Pin Count | Pin Count | 28 (DIP), 32 (PLCC) |
Standby Current | Standby Current | 100μA (max) |
Active Current | Active Current | 20mA (max) |
Instructions for Use:
Power Supply:
- Ensure that the Vcc supply voltage is within the range of 4.5V to 5.5V.
- The Vpp programming voltage should be set to 12.0V ± 0.5V.
Programming:
- To program the device, apply the Vpp voltage to the appropriate pin and follow the programming sequence specified in the datasheet.
- The write cycle time is 4ms (max).
Erasing:
- To erase the device, apply the Vpp voltage and follow the erase sequence specified in the datasheet.
- The erase cycle time is 1 second (max).
Reading:
- The read access time is 70ns (max). Ensure that the address lines are stable before initiating a read operation.
Temperature Considerations:
- The device is designed to operate in an industrial temperature range of -40°C to +85°C.
- Store the device in a temperature range of -65°C to +150°C.
Current Consumption:
- The standby current is 100μA (max).
- The active current is 20mA (max).
Package Handling:
- Handle the device with care to avoid damage to the pins.
- Follow proper ESD (Electrostatic Discharge) precautions when handling the device.
Data Retention:
- The data retention is typically 10 years under normal operating conditions.
Pin Configuration:
- Refer to the pinout diagram in the datasheet for correct pin connections.
Testing:
- Perform functional tests as per the test conditions specified in the datasheet to ensure proper operation.
View more about M27C1001-70B1 on main site