Parameter Symbol Min Typical Max Unit Description
Supply Voltage VDD 2.7 - 5.5 V Operating supply voltage range
Supply Current IDD - 100 - μA Quiescent current (typical)
Output Voltage Range VOUT - VDD-1.5 - V Output voltage range
Output Current IOUT - 200 - mA Maximum continuous output current
Load Regulation - - 0.5 - % Change in output voltage with load
Line Regulation - - 0.1 - %/V Change in output voltage with input voltage
Dropout Voltage VDROPOUT - 1.5 - V Minimum input-to-output voltage difference
Thermal Shutdown TSD - 150 - °C Temperature at which thermal shutdown occurs
Operating Temperature TOPR -40 - 125 °C Operating temperature range
Storage Temperature TSTG -65 - 150 °C Storage temperature range

Instructions for Use:

  1. Supply Voltage (VDD):

    • Ensure the supply voltage is within the range of 2.7V to 5.5V to avoid damage to the device.
  2. Supply Current (IDD):

    • The typical quiescent current is 100 μA. This value can vary depending on the operating conditions.
  3. Output Voltage Range (VOUT):

    • The output voltage should be set to a value between 0V and (VDD - 1.5V) to ensure proper operation.
  4. Output Current (IOUT):

    • The maximum continuous output current is 200 mA. Exceeding this value may cause the device to overheat or fail.
  5. Load Regulation:

    • The change in output voltage due to load variations is typically 0.5%. This ensures stable output under varying load conditions.
  6. Line Regulation:

    • The change in output voltage due to input voltage variations is typically 0.1% per volt. This ensures stable output even with fluctuations in the supply voltage.
  7. Dropout Voltage (VDROPOUT):

    • The minimum input-to-output voltage difference required for proper regulation is 1.5V. Ensure this condition is met to avoid dropout.
  8. Thermal Shutdown (TSD):

    • The device will automatically shut down if the junction temperature reaches 150°C to prevent damage. Allow the device to cool before resuming operation.
  9. Operating Temperature (TOPR):

    • The device is designed to operate within the temperature range of -40°C to 125°C. Ensure the ambient temperature does not exceed these limits.
  10. Storage Temperature (TSTG):

    • The device can be stored in temperatures ranging from -65°C to 150°C without damage. However, ensure it is brought to operating temperature before use.

Additional Notes:

  • Always refer to the datasheet for detailed specifications and application notes.
  • Use appropriate decoupling capacitors to stabilize the supply voltage and improve performance.
  • Ensure proper PCB layout and thermal management to maintain optimal performance and reliability.