DS1245Y-70

DS1245Y-70

Category: IC ChipsMemory

Specifications
SKU
931105
Details

BUY DS1245Y-70 https://www.utsource.net/itm/p/931105.html
1024k Nonvolatile SRAM
Parameter Symbol Min Typ Max Unit Description
Operating Voltage Vcc 2.0 3.0 5.5 V Supply voltage range
Standby Current Icc - 1.0 2.0 μA Current consumption in standby mode
Active Current Icc - 10 20 μA Current consumption in active mode
Output Voltage (High) VOH 2.4 3.0 5.0 V Output high voltage at 100 μA
Output Voltage (Low) VOL 0.0 0.4 0.6 V Output low voltage at 100 μA
Data Retention Time tDR - - 10 years Data retention time at 85°C
Operating Temperature Toper -40 - 85 °C Operating temperature range
Storage Temperature Tstg -65 - 150 °C Storage temperature range

Instructions for Using DS1245Y-70

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the specified range of 2.0V to 5.5V.
    • Use a stable power source to avoid fluctuations that could affect performance.
  2. Standby Mode:

    • To minimize power consumption, place the device in standby mode when not actively using it.
    • Standby current is typically between 1.0 μA and 2.0 μA.
  3. Active Mode:

    • When the device is in active mode, the current consumption increases to between 10 μA and 20 μA.
    • Ensure the system can handle this increased current draw.
  4. Output Levels:

    • The output high voltage (VOH) should be at least 2.4V and can go up to 5.0V when sourcing 100 μA.
    • The output low voltage (VOL) should be no more than 0.6V and typically around 0.4V when sinking 100 μA.
  5. Data Retention:

    • The device retains data for up to 10 years at a temperature of 85°C.
    • For longer data retention, store the device at lower temperatures.
  6. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C.
    • The storage temperature range is from -65°C to 150°C.
  7. Handling and Storage:

    • Handle the device with care to avoid static damage.
    • Store the device in a dry, cool environment to ensure long-term reliability.
  8. Programming:

    • Refer to the device datasheet for specific programming instructions and protocols.
    • Use appropriate programming tools and software to configure the device settings.
  9. Testing:

    • Before deploying the device in a final application, conduct thorough testing to ensure it meets all performance specifications.
    • Test under various conditions, including different voltages and temperatures, to verify reliability.
(For reference only)

View more about DS1245Y-70 on main site