AN17850A

AN17850A


Specifications
SKU
968149
Details

BUY AN17850A https://www.utsource.net/itm/p/968149.html
Silicon Monolithic Bipolar IC
Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 2.7 - 5.5 V Operating supply voltage range
Supply Current IDD - 1.5 3.0 mA Quiescent current at typical operating conditions
Output Current IOUT - 50 100 mA Maximum continuous output current
Output Voltage VOUT - 3.3 - V Regulated output voltage
Dropout Voltage VDROPOUT - 0.3 0.5 V Voltage difference between input and output when fully loaded
Load Regulation - - 0.5 1.0 % Change in output voltage with load
Line Regulation - - 0.1 0.5 % Change in output voltage with input voltage
Ripple Rejection - 60 70 80 dB Attenuation of input ripple at the output
Thermal Shutdown TSD - 150 170 °C Temperature at which the device shuts down to prevent damage
Operating Temperature TOPR -40 - 125 °C Ambient temperature range for operation

Instructions for Use

  1. Power Supply Connection:

    • Connect the positive terminal of the power supply to the VDD pin.
    • Connect the negative terminal (ground) of the power supply to the GND pin.
  2. Output Connection:

    • Connect the load to the VOUT pin.
    • Ensure the load does not exceed the maximum output current of 100 mA.
  3. Capacitors:

    • Place a 1 μF ceramic capacitor between VDD and GND as close to the device as possible to filter input noise.
    • Place a 1 μF ceramic capacitor between VOUT and GND to stabilize the output voltage.
  4. Thermal Considerations:

    • Ensure adequate heat dissipation if the device is operating near its maximum output current or in high ambient temperatures.
    • The device will automatically shut down if the junction temperature exceeds 150°C to prevent damage.
  5. PCB Layout:

    • Use a ground plane to help dissipate heat and reduce noise.
    • Keep traces short and wide to minimize resistance and inductance.
  6. Storage and Handling:

    • Store the device in a dry, cool place.
    • Handle with care to avoid static discharge, which can damage the device.
  7. Testing:

    • Before connecting the load, measure the output voltage to ensure it is within the expected range.
    • Monitor the temperature and current during operation to ensure the device is functioning correctly.
(For reference only)