Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage VCC 2.7 - 5.5 V -
Input Offset Voltage VOS -0.5 0 0.5 mV VCC = 3.0V to 5.5V, TA = 25°C
Input Bias Current IB - 1 - nA VCC = 3.0V to 5.5V, TA = 25°C
Input Voltage Range VI -0.3 - VCC + 0.3 V -
Output Voltage Swing VO 0 - VCC - 1.2 V RL = 10kΩ, VCC = 3.0V to 5.5V, TA = 25°C
Slew Rate SR - 1 - V/μs VCC = 3.0V to 5.5V, TA = 25°C
Bandwidth fBW - 10 - MHz VCC = 3.0V to 5.5V, TA = 25°C
Quiescent Current IQ - 2.8 - mA VCC = 3.0V to 5.5V, TA = 25°C
Common-Mode Rejection Ratio CMRR - 90 - dB VCC = 3.0V to 5.5V, TA = 25°C
Power-Down Mode Current IPD - 1 - μA VCC = 3.0V to 5.5V, TA = 25°C

Instructions for Use:

  1. Supply Voltage (VCC):

    • Ensure the supply voltage is within the range of 2.7V to 5.5V.
    • Connect the supply voltage to the VCC pin and ground to the GND pin.
  2. Input Signals:

    • The input signals should be within the range of -0.3V to VCC + 0.3V.
    • Avoid exceeding these limits to prevent damage to the device.
  3. Output Load:

    • The output can swing from 0V to VCC - 1.2V when connected to a 10kΩ load.
    • For optimal performance, ensure the load resistance is appropriate for the application.
  4. Power-Down Mode:

    • To enter power-down mode, set the shutdown pin to a high state.
    • In this mode, the current consumption drops to approximately 1μA.
  5. Temperature Considerations:

    • The device is designed to operate at temperatures from -40°C to 85°C.
    • Ensure the operating environment does not exceed these temperature limits.
  6. Slew Rate and Bandwidth:

    • The typical slew rate is 1V/μs and the bandwidth is 10MHz.
    • These parameters affect the speed and frequency response of the amplifier.
  7. Common-Mode Rejection Ratio (CMRR):

    • The CMRR is 90dB, which indicates good rejection of common-mode signals.
    • This is useful in applications where differential signals are used.
  8. Quiescent Current:

    • The quiescent current is typically 2.8mA, which should be considered in power budgeting.
  9. Mounting and Handling:

    • Handle the device with care to avoid static damage.
    • Follow standard ESD precautions during assembly and handling.
  10. Storage:

    • Store the device in a dry, cool place to prevent moisture damage.
    • Follow recommended storage conditions as specified in the datasheet.