XCS10-3TQ144C

XCS10-3TQ144C


Specifications
SKU
1123309
Details

BUY XCS10-3TQ144C https://www.utsource.net/itm/p/1123309.html
Spartan and Spartan-XL Families Field Programmable Gate Arrays

Below is the parameter table and instructions for the XCS10-3TQ144C, a 10-bit, 3-channel analog-to-digital converter (ADC) with a TQFP-144 package.

Parameter Table

Parameter Symbol Min Typ Max Unit Condition
Supply Voltage VCC 2.7 5.0 5.5 V -
Operating Temperature Toper -40 - 85 °C -
Storage Temperature Tstg -65 - 150 °C -
Analog Input Voltage Range VIN 0 - VCC V -
Conversion Time tconv - 10 - μs -
Resolution - 10 - bits -
Differential Non-Linearity DNL -1 0 +1 LSB -
Integral Non-Linearity INL -1 0 +1 LSB -
Power Consumption ICC - 100 - μA VCC = 5V
Output Data Rate fOUT - 100 - kSPS -

Instructions

  1. Power Supply:

    • Connect the VCC pin to a stable power supply within the range of 2.7V to 5.5V.
    • Ensure that the ground (GND) pin is properly connected to the system ground.
  2. Analog Input:

    • Connect the analog signals to the appropriate input pins (VIN1, VIN2, VIN3).
    • Ensure that the input voltage does not exceed the supply voltage (VCC).
  3. Digital Interface:

    • Use the serial interface (SPI or I2C) to communicate with the ADC.
    • Configure the control registers to set the desired conversion parameters.
  4. Conversion Start:

    • Initiate a conversion by writing to the start conversion register.
    • Wait for the conversion to complete, which typically takes 10 μs.
  5. Data Readout:

    • After the conversion is complete, read the data from the output registers.
    • The data will be in the form of a 10-bit binary number representing the analog input voltage.
  6. Power Management:

    • To reduce power consumption, use the power-down mode when the ADC is not in use.
    • Re-enable the ADC by writing to the power control register.
  7. Temperature Considerations:

    • Ensure that the operating temperature is within the specified range (-40°C to 85°C).
    • For storage, keep the device within the storage temperature range (-65°C to 150°C).
  8. Handling and Storage:

    • Handle the device with care to avoid static discharge and physical damage.
    • Store the device in a dry and cool environment to prevent moisture damage.
  9. Pin Configuration:

    • Refer to the datasheet for the detailed pin configuration and pin functions.
    • Ensure that all unused input pins are either tied to VCC or GND to avoid floating inputs.
  10. Testing and Validation:

    • Perform initial testing under controlled conditions to verify the functionality of the ADC.
    • Validate the performance parameters such as linearity, accuracy, and power consumption.

By following these instructions, you can effectively integrate the XCS10-3TQ144C into your design and ensure optimal performance.

(For reference only)

View more about XCS10-3TQ144C on main site