UC2909DW
Specifications
SKU
1207726
Details
BUY UC2909DW https://www.utsource.net/itm/p/1207726.html
CLASS-D VERTICAL DEFLECTION AMPLIFIER FOR 3 APP MONITOR/TV APPLICATIONS WITH 80 V INTERNAL FLYBACK GENERATOR
| Parameter | Description | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Input Voltage (Vcc) | Operating voltage range | 8.5 | - | 40 | V |
| Output Voltage (Vo) | Regulated output voltage | - | 5.1 | - | V |
| Quiescent Current (Iq) | Supply current at no load | - | 2.5 | - | mA |
| Output Current (Io) | Maximum output current | - | - | 1.5 | A |
| Dropout Voltage (Vdo) | Voltage difference between input and output for regulation | - | 1.5 | - | V |
| Load Regulation | Change in output voltage with load | - | 0.5 | - | % |
| Line Regulation | Change in output voltage with input voltage | - | 0.05 | - | % |
| Ripple Rejection | Ability to reject input ripple | - | 70 | - | dB |
| Thermal Shutdown Temperature | Temperature at which device shuts down | - | 160 | - | 掳C |
| Storage Temperature Range | Operating temperature range for storage | -40 | - | 125 | 掳C |
| Junction Temperature Range | Operating temperature range for junction | -40 | - | 150 | 掳C |
Instructions for Using UC2909DW
Power Supply Connection:
- Connect the input voltage (Vcc) to the appropriate pin, ensuring it is within the operating range of 8.5V to 40V.
- Ground the common ground (GND) pin.
Output Configuration:
- Connect the output pin (Vo) to the load.
- Ensure the load does not exceed the maximum output current of 1.5A.
Capacitor Selection:
- Place a bypass capacitor (typically 0.1渭F) close to the Vcc and GND pins to filter out noise.
- Use an output capacitor (typically 10渭F to 100渭F) to stabilize the output voltage and reduce ripple.
Thermal Management:
- Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
- Consider using a heatsink if the junction temperature exceeds 150掳C.
Protection Circuits:
- Implement overvoltage and short-circuit protection to safeguard the device and connected components.
- Monitor the thermal shutdown temperature to prevent damage from overheating.
Testing and Verification:
- Measure the output voltage to ensure it is within the specified range of 5.1V.
- Verify the load regulation and line regulation to ensure stable performance under varying conditions.
- Check the ripple rejection to ensure minimal noise on the output.
Storage and Handling:
- Store the device in a dry environment within the temperature range of -40掳C to 125掳C.
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
View more about UC2909DW on main site