BUY MC74HC174AN https://www.utsource.net/itm/p/1208872.html
Hex D Flip-Flop witth Common Clock and Reset
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | Operating | 2.0 | - | 6.0 | V |
Input Low Voltage | VIL | VCC = 4.5V to 6.0V | - | - | 1.5 | V |
Input High Voltage | VIH | VCC = 4.5V to 6.0V | 3.0 | - | - | V |
Output Low Voltage | VOL | IOL = 8 mA, VCC = 4.5V to 6.0V | - | 0.4 | - | V |
Output High Voltage | VOH | IOH = -0.4 mA, VCC = 4.5V to 6.0V | - | 2.4 | - | V |
Input Leakage Current | IIL | VCC = 0V to 6.0V | -1 | - | 1 | μA |
Output Leakage Current | IOL | VCC = 0V to 6.0V | -1 | - | 1 | μA |
Propagation Delay Time | tp | VCC = 4.5V to 6.0V, TA = 25°C | - | 11 | - | ns |
Power Dissipation | PD | Continuous | - | - | 100 | mW |
Operating Temperature Range | TA | Commercial | -40 | - | 85 | °C |
Instructions for Using the MC74HC174AN
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.0V to 6.0V.
- Connect the ground (GND) pin to a stable 0V reference.
Input Signals:
- Apply input signals (D1-D4) with voltages that meet the specified input low (VIL) and high (VIH) levels.
- Ensure input signals are clean and free from noise to avoid false triggering.
Output Signals:
- The output pins (Q1-Q4) will follow the state of the corresponding input pins when the clock (CLK) signal is applied.
- Use appropriate pull-up or pull-down resistors if needed to ensure proper logic levels.
Clock Signal:
- Apply a clock signal (CLK) to trigger the latching of input data to the outputs.
- Ensure the clock signal has a clean rising edge to avoid metastability issues.
Reset and Set:
- If the device includes reset (RST) or set (SET) pins, apply the appropriate signals to initialize or clear the flip-flops as needed.
- Ensure these signals are stable and meet the required voltage levels.
Propagation Delay:
- Account for the propagation delay time (tp) in your timing calculations to ensure reliable operation.
Temperature Considerations:
- Operate the device within the specified temperature range (-40°C to 85°C) to avoid damage or unreliable performance.
Power Dissipation:
- Monitor the power dissipation (PD) to ensure it does not exceed the maximum rating of 100 mW to prevent overheating.
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Follow proper ESD (Electrostatic Discharge) protection guidelines during handling and installation.
By following these instructions, you can ensure reliable and efficient operation of the MC74HC174AN D-type flip-flop.
(For reference only)View more about MC74HC174AN on main site