DG200ABA
Specifications
SKU
1467652
Details
BUY DG200ABA https://www.utsource.net/itm/p/1467652.html
IC SWITCH SPST DUAL TO100-10
Below is the parameter table and instructions for the DG200ABA, a digital isolator from Texas Instruments.
DG200ABA Parameter Table
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Supply Voltage (Input Side) | VDD1 | 3.0 | 5.0 | 5.5 | V | |
| Supply Voltage (Output Side) | VDD2 | 3.0 | 5.0 | 5.5 | V | |
| Input High Voltage | VIH | 2.0 | - | VDD1 | V | |
| Input Low Voltage | VIL | 0 | - | 0.8 | V | |
| Output High Voltage | VOH | 2.4 | - | VDD2-0.4 | V | IOH = -4 mA |
| Output Low Voltage | VOL | 0 | - | 0.4 | V | IOL = 4 mA |
| Propagation Delay (High to Low) | tPLH | 10 | 25 | 50 | ns | VDD1 = VDD2 = 5V, fIN = 1 MHz |
| Propagation Delay (Low to High) | tPHL | 10 | 25 | 50 | ns | VDD1 = VDD2 = 5V, fIN = 1 MHz |
| Maximum Data Rate | fMAX | - | - | 100 | Mbps | |
| Isolation Voltage | VIORM | - | - | 2500 | Vrms | 1 minute |
| Operating Temperature Range | Toperating | -40 | - | 125 | °C | |
| Storage Temperature Range | Tstorage | -65 | - | 150 | °C |
Instructions for Using the DG200ABA
Power Supply Connection:
- Connect VDD1 to the power supply on the input side.
- Connect VDD2 to the power supply on the output side.
- Ensure both VDD1 and VDD2 are within the specified range (3.0V to 5.5V).
Signal Input:
- Connect the digital signal to be isolated to the input pin (IN).
- The input signal should be within the valid logic levels defined by VIH and VIL.
Signal Output:
- The isolated output signal will be available at the output pin (OUT).
- Ensure the load connected to the output pin is within the specified current limits (IOH and IOL).
Propagation Delay:
- The propagation delay (tPLH and tPHL) should be considered when designing the system to ensure proper timing.
- For best performance, keep the propagation delay within the typical range (25 ns).
Isolation:
- The DG200ABA provides galvanic isolation up to 2500 Vrms for 1 minute.
- Ensure that the isolation barrier is not exceeded to avoid damage to the device.
Operating and Storage Conditions:
- Operate the device within the specified temperature range (-40°C to 125°C).
- Store the device within the storage temperature range (-65°C to 150°C).
Handling Precautions:
- Handle the device with care to avoid static discharge.
- Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
By following these parameters and instructions, you can effectively use the DG200ABA in your digital isolation applications.
(For reference only)View more about DG200ABA on main site