Details

BUY CD4007 https://www.utsource.net/itm/p/1542189.html
Multiple RS-232 Drivers and Receivers 20-TSSOP -40 to 85
Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 3 - 15 V Operating supply voltage range
Input Low Voltage VIL 0 - 0.8 V Maximum input low voltage for guaranteed low-level recognition
Input High Voltage VIH 2 - VDD V Minimum input high voltage for guaranteed high-level recognition
Output Low Voltage VOL 0 - 0.4 V Maximum output low voltage under specified load conditions
Output High Voltage VOH 2.4 - VDD - 0.1 V Minimum output high voltage under specified load conditions
Leakage Current ILK - - 卤100 nA Maximum leakage current at any pin
Propagation Delay Time td - 35 - ns Typical propagation delay time (for VDD = 10V)
Power Dissipation PD - - 100 mW Maximum power dissipation per package
Operating Temperature Range TA -40 - 85 掳C Ambient temperature range

Instructions for Using CD4007

  1. Supply Voltage:

    • Ensure the supply voltage (VDD) is within the specified range (3V to 15V). Exceeding these limits can damage the device.
  2. Input Levels:

    • For reliable operation, ensure that input voltages (VIL and VIH) are within the specified ranges. Inputs below 0.8V are recognized as low, and inputs above 2V are recognized as high.
  3. Output Levels:

    • The output low voltage (VOL) should not exceed 0.4V, and the output high voltage (VOH) should be at least 2.4V (or VDD - 0.1V) to ensure proper logic levels.
  4. Leakage Current:

    • Keep the leakage current (ILK) below 卤100nA to avoid unexpected behavior or increased power consumption.
  5. Propagation Delay:

    • The typical propagation delay time (td) is 35ns at VDD = 10V. This value may vary with different supply voltages and temperatures.
  6. Power Dissipation:

    • Do not exceed the maximum power dissipation (PD) of 100mW to prevent overheating and potential damage to the device.
  7. Operating Temperature:

    • The device is designed to operate within an ambient temperature range of -40掳C to 85掳C. Ensure the operating environment stays within this range to maintain reliability.
  8. Handling Precautions:

    • Handle the CD4007 with care to avoid static discharge, which can damage the device. Use proper ESD protection measures when handling and installing the component.
  9. Schematic Design:

    • When designing circuits, ensure that all connections are correct and that the device is properly decoupled with capacitors to filter out noise and stabilize the supply voltage.
  10. Testing:

    • Test the device in a controlled environment to verify its functionality before integrating it into a larger system. Use appropriate test equipment and follow safety guidelines.
(For reference only)

View more about CD4007 on main site