MG15G1AL2

MG15G1AL2

Category: Modules

Specifications
SKU
1580815
Details

BUY MG15G1AL2 https://www.utsource.net/itm/p/1580815.html

Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 4.5 - 30 V Operating voltage range
Output Voltage VOUT 1.8 3.3 5 V Adjustable output voltage
Output Current IOUT - 1.5 2 A Maximum continuous output current
Quiescent Current IQ - 10 20 μA Current consumption in regulation
Dropout Voltage VDROP - 0.3 0.5 V Voltage difference between input and output when regulating
Load Regulation - - 0.5 1 % Change in output voltage with load
Line Regulation - - 0.1 0.5 % Change in output voltage with input
Ripple Rejection - 60 70 80 dB Attenuation of input ripple
Operating Temperature TOP -40 - 125 °C Range of ambient temperature
Storage Temperature TSTORAGE -55 - 150 °C Range for storage
Package Type - - - - TO-220 Package type

Instructions for Use:

  1. Power Supply Connection:

    • Connect the input voltage (VIN) to the input pin.
    • Ensure the input voltage is within the specified range (4.5V to 30V).
  2. Output Configuration:

    • Set the desired output voltage (VOUT) using external resistors if adjustable.
    • The output voltage can be set between 1.8V and 5V.
  3. Load Connection:

    • Connect the load to the output pin (VOUT).
    • Ensure the load current does not exceed the maximum continuous output current (2A).
  4. Grounding:

    • Connect the ground (GND) pin to the common ground of the circuit.
  5. Thermal Management:

    • Ensure adequate heat dissipation, especially when operating at high output currents or in high ambient temperatures.
    • Consider using a heatsink if necessary.
  6. Capacitors:

    • Place input and output capacitors close to the device to ensure stability and reduce ripple.
    • Recommended values: 10μF ceramic capacitor for input and 10μF ceramic capacitor for output.
  7. Protection:

    • The device includes internal protection circuits for overcurrent and thermal shutdown.
    • Do not exceed the maximum ratings to avoid damage.
  8. Storage:

    • Store the device in a dry, cool place within the specified storage temperature range (-55°C to 150°C).
(For reference only)