Details
BUY AK4114VQ https://www.utsource.net/itm/p/1714963.html
HIGH FEATURE 192KHZ 24BIT DIGITAL AUDIO INTERFACE TRANSCEIVER
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | Operating | 2.7 | 3.3 | 5.5 | V |
Power Consumption | IDD | All channels active | - | 200 | - | mA |
Operating Temperature | Toper | - | -40 | - | 85 | °C |
Storage Temperature | Tstg | - | -65 | - | 150 | °C |
Input Voltage Range | VIN | Differential | -1 | - | 1 | V |
Output Voltage Swing | VOUT | Differential | -0.5 | - | 0.5 | V |
Signal-to-Noise Ratio | SNR | A-weighted | - | 100 | - | dB |
Total Harmonic Distortion | THD | 1kHz, -1dBFS | - | 0.005 | - | % |
Channel Separation | CS | 1kHz | - | 100 | - | dB |
Clock Frequency Range | fCLK | - | 32 | - | 192 | kHz |
Jitter Tolerance | JTOL | 10kHz to 20MHz | - | 10 | - | ps |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VDD) is within the specified range of 2.7V to 5.5V.
- Connect a decoupling capacitor (0.1μF) close to the power supply pins to reduce noise.
Input Signals:
- The differential input voltage range should be between -1V and +1V.
- Ensure the input signals are properly terminated to avoid reflections and signal degradation.
Output Configuration:
- The output voltage swing is differential and should be within -0.5V to +0.5V.
- Use appropriate load resistors to match the output impedance of the device.
Clocking:
- The clock frequency range supported is from 32kHz to 192kHz.
- Ensure the clock signal is stable and has minimal jitter to maintain performance.
Temperature Considerations:
- The operating temperature range is -40°C to 85°C.
- Store the device in temperatures ranging from -65°C to 150°C to ensure longevity.
Signal Quality:
- Monitor the signal-to-noise ratio (SNR) and total harmonic distortion (THD) to ensure high-quality audio performance.
- Channel separation should be maintained at 100dB for optimal performance.
Jitter Management:
- The device can tolerate up to 10ps of jitter in the clock signal.
- Use low-jitter clock sources and proper PCB layout techniques to minimize jitter.
Installation and Handling:
- Handle the device with care to avoid static damage.
- Follow standard ESD precautions during installation and handling.
Testing and Verification:
- After installation, verify all connections and parameters to ensure the device is functioning correctly.
- Use test signals to validate the performance of the device.
For detailed specifications and additional information, refer to the AK4114VQ datasheet provided by the manufacturer.
(For reference only)View more about AK4114VQ on main site