Details
BUY FAN73711 https://www.utsource.net/itm/p/1905210.html
| Parameter | Symbol | Test Conditions | Min | Typical | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | - | 4.5 | - | 20 | V |
| Operating Junction Temperature | Tj | - | -40 | - | 150 | °C |
| Gate Charge | Qg | Vgs = 15V, Id = 10A | - | 36 | - | nC |
| Input Capacitance | Cin | Vgs = 12V | - | 1400 | - | pF |
| Output Capacitance | Cout | Vds = 12V | - | 380 | - | pF |
| Turn-On Delay Time | td(on) | Vgs = 12V, Id = 10A | - | 28 | - | ns |
| Turn-Off Delay Time | td(off) | Vgs = 12V, Id = 10A | - | 25 | - | ns |
| Rise Time | tr | Vgs = 12V, Id = 10A | - | 20 | - | ns |
| Fall Time | tf | Vgs = 12V, Id = 10A | - | 20 | - | ns |
| Continuous Drain Current | Id | Vds = 100V, Tc = 25°C | - | 10 | - | A |
| Peak Drain Current | Idp | Vds = 100V, Tc = 25°C | - | 20 | - | A |
| Drain-Source Breakdown Voltage | BVdss | Id = 250μA, Tj = 25°C | - | 100 | - | V |
Instructions for Use:
Supply Voltage (Vcc):
- Ensure the supply voltage is within the range of 4.5V to 20V to avoid damage to the device.
Operating Junction Temperature (Tj):
- The device can operate over a temperature range from -40°C to 150°C. Ensure proper heat dissipation to maintain the junction temperature within this range.
Gate Charge (Qg):
- The gate charge is 36 nC at Vgs = 15V and Id = 10A. This parameter is crucial for determining the drive requirements.
Input Capacitance (Cin):
- The input capacitance is 1400 pF at Vgs = 12V. This affects the switching speed and drive circuit design.
Output Capacitance (Cout):
- The output capacitance is 380 pF at Vds = 12V. This parameter influences the turn-off characteristics.
Turn-On and Turn-Off Delay Times (td(on), td(off)):
- The turn-on delay time is 28 ns and the turn-off delay time is 25 ns at Vgs = 12V and Id = 10A. These times help in designing the timing of the drive signals.
Rise and Fall Times (tr, tf):
- The rise time is 20 ns and the fall time is 20 ns at Vgs = 12V and Id = 10A. These parameters are important for minimizing switching losses.
Continuous Drain Current (Id):
- The continuous drain current is 10A at Vds = 100V and Tc = 25°C. Ensure that the load does not exceed this current to prevent overheating.
Peak Drain Current (Idp):
- The peak drain current is 20A at Vds = 100V and Tc = 25°C. This is the maximum current the device can handle for short durations.
Drain-Source Breakdown Voltage (BVdss):
- The drain-source breakdown voltage is 100V at Id = 250μA and Tj = 25°C. Do not exceed this voltage to avoid damaging the device.
Additional Notes:
- Always refer to the datasheet for more detailed information and specific application notes.
- Proper PCB layout and thermal management are essential for reliable operation.
- Use appropriate decoupling capacitors to ensure stable power supply and reduce noise.
View more about FAN73711 on main site