Details
BUY FS100R12KS4 https://www.utsource.net/itm/p/2167253.html
Insulated Gate Bipolar Transistor, 130A I(C), 1200V V(BR)CES, N-Channel, MODULE-39
Parameter | Symbol | Min | Typical | Max | Unit | Conditions/Notes |
---|---|---|---|---|---|---|
Forward Voltage | VF | - | 1.8 | 2.3 | V | @ IF = 25A, Tj = 25°C |
Reverse Recovery Time | trr | - | 120 | 150 | ns | @ IR = 25A, Tj = 25°C |
Reverse Recovery Charge | Qrr | - | 200 | 250 | nC | @ IR = 25A, Tj = 25°C |
Reverse Breakdown Voltage | VBR | 1200 | - | - | V | @ IR = 1mA, Tj = 25°C |
Thermal Resistance | Rth(j-c) | - | 0.1 | 0.15 | K/W | Junction to Case |
Maximum Junction Temperature | Tj(max) | - | - | 175 | °C | |
Storage Temperature | Tstg | -55 | - | 150 | °C | |
Operating Temperature | Top | -40 | - | 125 | °C |
Instructions:
Handling and Storage:
- Store the device in a dry, cool place away from direct sunlight.
- Handle the device with care to avoid mechanical stress or damage.
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Use appropriate torque when mounting the device to the heatsink to ensure good thermal contact.
Electrical Connections:
- Connect the device according to the datasheet pinout diagram.
- Use short, low-inductance leads for high-frequency applications to minimize parasitic effects.
Reverse Voltage Application:
- Do not exceed the maximum reverse breakdown voltage (VBR) to prevent device failure.
- Ensure that the reverse voltage is applied slowly to avoid transient overvoltage conditions.
Forward Current:
- Limit the forward current (IF) to the maximum rated value to prevent overheating and potential damage.
- Consider derating the forward current at higher temperatures to ensure reliable operation.
Thermal Management:
- Monitor the junction temperature (Tj) during operation to ensure it remains below the maximum allowed value.
- Use thermal simulation tools to optimize the thermal design if necessary.
Testing and Validation:
- Perform thorough testing under actual operating conditions to validate the device performance.
- Follow the recommended test procedures outlined in the datasheet for accurate results.
View more about FS100R12KS4 on main site