4.8 kHz Ultralow Noise 24-Bit Sigma-Delta ADC with PGA
Parameter Description Min Typ Max Unit
Supply Voltage (VDD) Operating supply voltage 2.7 - 5.25 V
Reference Voltage (VREF) Internal reference voltage 2.5 4.096 - V
Input Range Differential input range ±2.5 - ±4.096 V
Input Impedance Differential input impedance - 10 -
Common-Mode Rejection Ratio (CMRR) Common-mode rejection ratio at 50/60 Hz - 110 - dB
Power Supply Rejection Ratio (PSRR) Power supply rejection ratio at 50/60 Hz - 110 - dB
Noise-Free Code Resolution Number of noise-free bits at 4.7 SPS - 23 - bits
Output Data Rate Programmable output data rate 0.78125 - 4700 SPS
Integral Nonlinearity (INL) Integral nonlinearity error - ±1 - LSB
Differential Nonlinearity (DNL) Differential nonlinearity error - ±1 - LSB
Offset Error Initial offset error - ±1 - LSB
Gain Error Initial gain error - ±10 - ppm
Temperature Coefficient (Offset) Temperature coefficient of offset - ±0.01 - LSB/°C
Temperature Coefficient (Gain) Temperature coefficient of gain - ±0.1 - ppm/°C
Operating Temperature Range Ambient operating temperature range -40 - 125 °C
Storage Temperature Range Storage temperature range -65 - 150 °C
Package Package type - - - 24-lead TSSOP
Pin Configuration Pin configuration - - - See datasheet

Instructions for Using AD7190BRUZ:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the range of 2.7V to 5.25V.
    • Connect the reference voltage (VREF) to the appropriate pin if using an external reference.
  2. Input Configuration:

    • Configure the differential inputs (AIN1, AIN2, etc.) based on the desired input range (±2.5V or ±4.096V).
    • Ensure the common-mode voltage is within the specified range for proper operation.
  3. Output Data Rate:

    • Set the output data rate (ODR) using the configuration registers. The ODR can be programmed from 0.78125 SPS to 4700 SPS.
  4. Calibration:

    • Perform initial calibration to correct for offset and gain errors. This can be done using the internal self-calibration or system calibration features.
  5. Noise Management:

    • For low-noise applications, use the lower output data rates to achieve higher noise-free code resolution.
  6. Temperature Considerations:

    • Monitor the temperature to ensure it stays within the operating range (-40°C to 125°C). Use the temperature coefficients to account for drift.
  7. Pin Connections:

    • Refer to the pin configuration section of the datasheet for detailed information on connecting the pins.
  8. Communication:

    • Use the SPI interface to communicate with the AD7190BRUZ. Ensure the communication protocol is correctly implemented.
  9. Power-Up Sequence:

    • Follow the recommended power-up sequence to avoid any potential issues during initialization.
  10. Storage and Handling:

    • Store the device in a controlled environment within the storage temperature range (-65°C to 150°C).
    • Handle the device with care to prevent damage from electrostatic discharge (ESD).

For more detailed information, refer to the AD7190BRUZ datasheet and application notes provided by Analog Devices.