AK6420AF

AK6420AF

Category: IC ChipsMemory

Specifications
SKU
4196398
Details

BUY AK6420AF https://www.utsource.net/itm/p/4196398.html
2K / 4K / 8Kbit Serial CMOS EEPROM
Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 1.7 - 3.6 V Operating supply voltage range
Standby Current ISB - 1 - μA Current consumption in standby mode
Operating Current IOP - 5 - mA Current consumption in operating mode
Output Data Rate ODR 1 - 100 Hz Output data rate range
Sensitivity (X, Y Axis) SX, SY 30 60 90 LSB/g Sensitivity for X and Y axes
Sensitivity (Z Axis) SZ 30 60 90 LSB/g Sensitivity for Z axis
Measurement Range ±g 2 - 8 g Measurement range for acceleration
Bandwidth BW 0.5 - 50 Hz Bandwidth of the sensor
Temperature Range Toper -40 - 85 °C Operating temperature range
Package - - - - LGA-16 Package type

Instructions for Using the AK6420AF

  1. Power Supply:

    • Connect the VDD pin to a power supply within the range of 1.7V to 3.6V.
    • Ensure the power supply is stable to avoid noise and interference.
  2. Ground Connection:

    • Connect the GND pin to the system ground to ensure proper operation and noise reduction.
  3. Output Data Rate (ODR):

    • Set the desired output data rate using the configuration registers. The ODR can be set between 1 Hz and 100 Hz.
  4. Measurement Range:

    • Configure the measurement range (±2g, ±4g, ±8g) based on the application requirements using the configuration registers.
  5. Sensitivity Adjustment:

    • Adjust the sensitivity for the X, Y, and Z axes as needed. The typical sensitivity is 60 LSB/g.
  6. Bandwidth Configuration:

    • Set the bandwidth to match the application requirements. The bandwidth can be set between 0.5 Hz and 50 Hz.
  7. Data Readout:

    • Use the I2C or SPI interface to read the acceleration data from the sensor. Refer to the datasheet for specific register addresses and communication protocols.
  8. Temperature Considerations:

    • Ensure the operating temperature is within the specified range (-40°C to 85°C) to maintain accuracy and reliability.
  9. Standby Mode:

    • To reduce power consumption, put the sensor into standby mode when not in use by setting the appropriate register bits.
  10. Handling and Mounting:

    • Handle the sensor with care to avoid mechanical stress and damage.
    • Mount the sensor in a stable position to minimize vibration and noise.

For detailed register settings and advanced configurations, refer to the AK6420AF datasheet and application notes provided by the manufacturer.

(For reference only)

View more about AK6420AF on main site