BUY CY7C1021BN-12VXC https://www.utsource.net/itm/p/4355939.html
1-Mbit (64K x 16) Static RAM
Parameter | Description | Value |
---|---|---|
Device Type | 8K x 9 Non-Volatile Static RAM (NVSRAM) | |
Package Type | 32-Pin Plastic Quad Flat Pack (PQFP) | |
Operating Voltage (Vcc) | Supply Voltage Range | 4.5V to 5.5V |
Standby Current (Icc) | Current Consumption in Standby Mode | 20 μA (max) |
Active Current (Icc) | Current Consumption in Active Mode | 15 mA (max) |
Access Time (tAA) | Access Time from Address Valid to Data Valid | 12 ns (max) |
Data Retention Time | Time Data is Retained without Power | 10 years (min) |
Temperature Range | Operating Temperature Range | -40°C to +85°C |
Write Cycle Time (tWC) | Minimum Write Cycle Time | 12 ns (max) |
Data Hold Time (tDH) | Minimum Data Hold Time | 0 ns |
Address Setup Time (tAS) | Minimum Address Setup Time | 3 ns (min) |
Data Setup Time (tDS) | Minimum Data Setup Time | 3 ns (min) |
Output Enable Time (tOE) | Minimum Output Enable Time | 3 ns (min) |
Chip Enable Time (tCE) | Minimum Chip Enable Time | 3 ns (min) |
Write Enable Time (tWE) | Minimum Write Enable Time | 3 ns (min) |
Power-down Time (tPD) | Minimum Time to Enter Power-down Mode | 3 ns (min) |
Power-up Time (tPU) | Minimum Time to Exit Power-down Mode | 3 ns (min) |
Storage Temperature | Temperature Range for Storage | -65°C to +150°C |
Instructions for Use
Power Supply:
- Ensure the supply voltage (Vcc) is within the specified range of 4.5V to 5.5V.
- Connect the ground (GND) pin to a stable ground reference.
Addressing:
- Apply the address signals (A0-A12) to the address pins before the address setup time (tAS).
- Maintain the address signals stable during the access time (tAA).
Data Input/Output:
- Data input should be applied to the data pins (D0-D8) before the data setup time (tDS).
- Data output will be valid after the access time (tAA) if the output enable (OE) is active.
Control Signals:
- The chip enable (CE) signal must be low to enable the device.
- The write enable (WE) signal must be low to perform a write operation.
- The output enable (OE) signal must be low to enable data output.
Power Management:
- To enter power-down mode, set the power-down (PD) signal high.
- To exit power-down mode, set the power-down (PD) signal low and wait for the power-up time (tPU).
Data Retention:
- Data is retained for up to 10 years without power.
- For optimal data retention, avoid exposing the device to extreme temperatures outside the storage temperature range.
Handling:
- Handle the device with care to avoid damage to the pins and package.
- Follow proper ESD (Electrostatic Discharge) precautions to prevent damage to the device.
Testing:
- Before integrating the device into a system, perform basic functional tests to ensure it meets the specified parameters.
For more detailed information, refer to the datasheet provided by Cypress Semiconductor.