Details
BUY MC33364DR2G https://www.utsource.net/itm/p/4671271.html
Critical Conduction GreenLine TM SMPS Controller
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Input Voltage (VIN) | Operating voltage range | 8.5 | - | 72 | V |
Output Current (IOUT) | Continuous output current | - | 100 | 150 | mA |
Dropout Voltage (VDO) | Voltage difference between VIN and VOUT for regulation | - | 1.2 | - | V |
Quiescent Current (IQ) | Current consumed by the regulator when no load is applied | - | 10 | - | mA |
Thermal Shutdown Temperature (TSD) | Temperature at which the device shuts down to prevent damage | - | - | 160 | °C |
Protection Features | Built-in protection mechanisms | Overcurrent, Overtemperature | - | - | - |
Operating Temperature Range (TA) | Ambient temperature range for operation | -40 | - | 125 | °C |
Storage Temperature Range (TSTG) | Temperature range for storage | -65 | - | 150 | °C |
Instructions for Using MC33364DR2G
Power Supply Connection:
- Connect the input voltage (VIN) to the positive terminal of the power supply.
- Ensure the input voltage is within the specified operating range (8.5V to 72V).
Output Connection:
- Connect the output (VOUT) to the load or circuit requiring regulated power.
- The maximum continuous output current should not exceed 150mA.
Ground Connection:
- Ensure a common ground connection between the input and output circuits.
Capacitors:
- Place a 1μF ceramic capacitor close to the input pin to stabilize the input voltage.
- Place a 1μF ceramic capacitor close to the output pin to stabilize the output voltage.
Thermal Management:
- Ensure adequate heat dissipation if operating near the maximum output current or in high ambient temperatures.
- Use a heatsink if necessary to keep the junction temperature below the thermal shutdown threshold (160°C).
Protection:
- The device includes built-in overcurrent and overtemperature protection.
- Do not bypass these protections as they are crucial for preventing damage to the device.
Storage:
- Store the device in a dry environment within the specified storage temperature range (-65°C to 150°C).
Handling:
- Handle with care to avoid static discharge, which can damage the device.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
Testing:
- Before connecting to the final application, test the device with a known load to ensure proper regulation and stability.
View more about MC33364DR2G on main site