MC33364DR2G

MC33364DR2G

Category: IC Chips

Specifications
SKU
4671271
Details

BUY MC33364DR2G https://www.utsource.net/itm/p/4671271.html
Critical Conduction GreenLine TM SMPS Controller
Parameter Description Min Typ Max Unit
Input Voltage (VIN) Operating voltage range 8.5 - 72 V
Output Current (IOUT) Continuous output current - 100 150 mA
Dropout Voltage (VDO) Voltage difference between VIN and VOUT for regulation - 1.2 - V
Quiescent Current (IQ) Current consumed by the regulator when no load is applied - 10 - mA
Thermal Shutdown Temperature (TSD) Temperature at which the device shuts down to prevent damage - - 160 °C
Protection Features Built-in protection mechanisms Overcurrent, Overtemperature - - -
Operating Temperature Range (TA) Ambient temperature range for operation -40 - 125 °C
Storage Temperature Range (TSTG) Temperature range for storage -65 - 150 °C

Instructions for Using MC33364DR2G

  1. Power Supply Connection:

    • Connect the input voltage (VIN) to the positive terminal of the power supply.
    • Ensure the input voltage is within the specified operating range (8.5V to 72V).
  2. Output Connection:

    • Connect the output (VOUT) to the load or circuit requiring regulated power.
    • The maximum continuous output current should not exceed 150mA.
  3. Ground Connection:

    • Ensure a common ground connection between the input and output circuits.
  4. Capacitors:

    • Place a 1μF ceramic capacitor close to the input pin to stabilize the input voltage.
    • Place a 1μF ceramic capacitor close to the output pin to stabilize the output voltage.
  5. Thermal Management:

    • Ensure adequate heat dissipation if operating near the maximum output current or in high ambient temperatures.
    • Use a heatsink if necessary to keep the junction temperature below the thermal shutdown threshold (160°C).
  6. Protection:

    • The device includes built-in overcurrent and overtemperature protection.
    • Do not bypass these protections as they are crucial for preventing damage to the device.
  7. Storage:

    • Store the device in a dry environment within the specified storage temperature range (-65°C to 150°C).
  8. Handling:

    • Handle with care to avoid static discharge, which can damage the device.
    • Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
  9. Testing:

    • Before connecting to the final application, test the device with a known load to ensure proper regulation and stability.
(For reference only)

View more about MC33364DR2G on main site