Details
BUY MX29F040QC-70G https://www.utsource.net/itm/p/4834806.html
4M-BIT [512KX8] CMOS EQUAL SECTOR FLASH MEMORY
| Parameter | Symbol | Conditions | Min | Typical | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | Operating | 2.7 | - | 3.6 | V |
| Standby Current | Icc | Vcc = 3.0V | 1 | - | 5 | μA |
| Active Current | Icc | Vcc = 3.0V | 10 | - | 30 | mA |
| Access Time | tacc | Vcc = 3.0V | 70 | - | - | ns |
| Block Erase Time | tBE | 100 | - | 400 | ms | |
| Chip Erase Time | tCE | 1000 | - | 4000 | ms | |
| Program Time | tP | 1 | - | 5 | μs | |
| Data Retention | 10 | - | - | years | ||
| Operating Temperature | Commercial Grade | 0 | - | 70 | °C | |
| Industrial Temperature | Industrial Grade | -40 | - | 85 | °C |
Instructions for MX29F040QC-70G
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
- Use decoupling capacitors close to the power pins to minimize noise.
Initialization:
- Apply the supply voltage (Vcc) before any other signals.
- Ensure the chip select (CS) is high during power-up to prevent unintended operations.
Read Operation:
- Set the chip select (CS) low.
- Apply the address to the address lines (A0-A18).
- The data will be available on the data lines (D0-D7) after the access time (tacc).
Write Operation:
- Write operations include programming and erasing.
- Before writing, ensure the write enable latch (WEL) is set by sending the Write Enable (WREN) command.
- After writing, send the Write Disable (WRDI) command to reset the WEL.
Program Operation:
- Set CS low.
- Send the Write Enable (WREN) command.
- Send the Program command (0x02).
- Apply the address to the address lines.
- Apply the data to the data lines.
- Wait for the program time (tP) to complete.
Erase Operation:
- Set CS low.
- Send the Write Enable (WREN) command.
- For block erase, send the Block Erase command (0x52) followed by the block address.
- For chip erase, send the Chip Erase command (0x60).
- Wait for the appropriate erase time (tBE or tCE) to complete.
Status Register Read:
- Set CS low.
- Send the Read Status Register (RDSR) command (0x05).
- The status register will be read from the data lines.
Temperature Considerations:
- Ensure the operating temperature is within the specified range for the grade of the device (Commercial or Industrial).
Data Retention:
- The device guarantees data retention for at least 10 years under normal operating conditions.
Handling:
- Handle the device with care to avoid static damage.
- Follow proper soldering techniques to ensure reliable connections.