MX29F040QC-70G

MX29F040QC-70G


Specifications
SKU
4834806
Details

BUY MX29F040QC-70G https://www.utsource.net/itm/p/4834806.html
4M-BIT [512KX8] CMOS EQUAL SECTOR FLASH MEMORY
Parameter Symbol Conditions Min Typical Max Unit
Supply Voltage Vcc Operating 2.7 - 3.6 V
Standby Current Icc Vcc = 3.0V 1 - 5 μA
Active Current Icc Vcc = 3.0V 10 - 30 mA
Access Time tacc Vcc = 3.0V 70 - - ns
Block Erase Time tBE 100 - 400 ms
Chip Erase Time tCE 1000 - 4000 ms
Program Time tP 1 - 5 μs
Data Retention 10 - - years
Operating Temperature Commercial Grade 0 - 70 °C
Industrial Temperature Industrial Grade -40 - 85 °C

Instructions for MX29F040QC-70G

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
    • Use decoupling capacitors close to the power pins to minimize noise.
  2. Initialization:

    • Apply the supply voltage (Vcc) before any other signals.
    • Ensure the chip select (CS) is high during power-up to prevent unintended operations.
  3. Read Operation:

    • Set the chip select (CS) low.
    • Apply the address to the address lines (A0-A18).
    • The data will be available on the data lines (D0-D7) after the access time (tacc).
  4. Write Operation:

    • Write operations include programming and erasing.
    • Before writing, ensure the write enable latch (WEL) is set by sending the Write Enable (WREN) command.
    • After writing, send the Write Disable (WRDI) command to reset the WEL.
  5. Program Operation:

    • Set CS low.
    • Send the Write Enable (WREN) command.
    • Send the Program command (0x02).
    • Apply the address to the address lines.
    • Apply the data to the data lines.
    • Wait for the program time (tP) to complete.
  6. Erase Operation:

    • Set CS low.
    • Send the Write Enable (WREN) command.
    • For block erase, send the Block Erase command (0x52) followed by the block address.
    • For chip erase, send the Chip Erase command (0x60).
    • Wait for the appropriate erase time (tBE or tCE) to complete.
  7. Status Register Read:

    • Set CS low.
    • Send the Read Status Register (RDSR) command (0x05).
    • The status register will be read from the data lines.
  8. Temperature Considerations:

    • Ensure the operating temperature is within the specified range for the grade of the device (Commercial or Industrial).
  9. Data Retention:

    • The device guarantees data retention for at least 10 years under normal operating conditions.
  10. Handling:

    • Handle the device with care to avoid static damage.
    • Follow proper soldering techniques to ensure reliable connections.
(For reference only)

View more about MX29F040QC-70G on main site