| Parameter | Value | Notes |
|---|---|---|
| Device Type | 2M x 32 SDRAM | |
| Package Type | 54-pin TSOP II | |
| Supply Voltage (Vcc) | 3.3V ± 0.3V | |
| Operating Temperature | -40°C to +85°C | Industrial temperature range |
| Data Width | 32 bits | |
| Access Time (tAC) | 7 ns | |
| Cycle Time (tRC) | 15 ns | |
| Row Address Bits | 12 bits | |
| Column Address Bits | 9 bits | |
| Bank Address Bits | 2 bits | |
| Refresh Cycle | 8192 refresh cycles per 64 ms | |
| Power Consumption | 200 mW (Typical) | Active mode |
| Standby Power | 10 mW (Typical) | Standby mode |
| Input Voltage (Vccq) | 3.3V ± 0.3V | I/O supply voltage |
| Output Drive Strength | 24 mA (Max) | |
| Slew Rate Control | Programmable | |
| CAS Latency | CL = 3 | |
| Write Recovery Time | 7 ns (Minimum) | |
| Data Hold Time | 0.5 ns (Minimum) | |
| Data Setup Time | 2.5 ns (Minimum) | |
| Address Setup Time | 2.5 ns (Minimum) | |
| Clock Period | 10 ns (Maximum) | |
| Ordering Code | MT48LC2M32B2TG-7IT:G |
Instructions for Use:
Power Supply:
- Ensure that the Vcc and Vccq are within the specified range (3.3V ± 0.3V).
- Use decoupling capacitors close to the power pins to minimize noise.
Clock Signal:
- The clock signal should be clean and have a period of no more than 10 ns.
- Use a stable clock source to avoid timing issues.
Address and Data Lines:
- Address lines (A0-A11, BA0-BA1) must be stable before the address setup time.
- Data lines (DQ0-DQ31) should be held stable during the data setup and hold times.
Refresh:
- Perform 8192 refresh cycles every 64 ms to maintain data integrity.
- Use auto-refresh or self-refresh modes as needed.
Write Operations:
- Ensure that the write recovery time (tWR) is at least 7 ns to prevent data corruption.
- Data should be held on the data lines for the required setup and hold times.
Read Operations:
- The access time (tAC) is 7 ns, so ensure that the read cycle is timed accordingly.
- Use appropriate CAS latency settings (CL = 3).
Standby Mode:
- To reduce power consumption, use the standby mode by deactivating all banks and entering self-refresh or power-down states.
Slew Rate Control:
- Adjust the slew rate control to match the system requirements and reduce EMI.
Handling:
- Handle the device with care to avoid static damage.
- Follow ESD protection guidelines during handling and installation.
Storage:
- Store the device in a dry, cool environment to prevent moisture damage.
- Use anti-static packaging when storing or transporting the device.