Details
BUY MT48LC32M16A2P-75C https://www.utsource.net/itm/p/4906540.html
| Parameter | Description | Value |
|---|---|---|
| Device Type | Memory Device | 32 Mbit (4M x 8, 2M x 16, 1M x 32) SDRAM |
| Package | Package Type | 54-pin TSOP (Thin Small Outline Package) |
| Supply Voltage (VCC) | Operating Voltage Range | 2.5V ± 0.2V |
| Supply Voltage (VCCQ) | I/O Supply Voltage | 2.5V ± 0.2V |
| Data Width | Data Bus Width | 16 bits |
| Row Address Bits | Number of Row Address Bits | 13 bits |
| Column Address Bits | Number of Column Address Bits | 9 bits |
| Bank Address Bits | Number of Bank Address Bits | 2 bits |
| Access Time (tAC) | Access Time from Clock Edge to Data Valid | 7.5 ns max |
| Cycle Time (tRC) | Row Cycle Time | 60 ns max |
| Refresh Cycle Time (tREF) | Refresh Cycle Time | 64 ms max |
| Operating Temperature | Industrial Temperature Range | -40°C to +85°C |
| Storage Temperature | Storage Temperature Range | -65°C to +150°C |
| Power Consumption | Active Power Consumption | 1.0W typ (at 133 MHz) |
| Standby Power Consumption | Standby Power Consumption | 0.05W typ |
Instructions for Use:
Power Supply:
- Ensure that both VCC and VCCQ are supplied with 2.5V ± 0.2V.
- Use decoupling capacitors close to the power supply pins to minimize noise.
Addressing:
- The device supports 13 row address bits, 9 column address bits, and 2 bank address bits.
- Address lines should be stable before the rising edge of the clock signal.
Clock Signal:
- The device operates with a single-ended clock input (CLK).
- Ensure the clock signal is clean and has a stable frequency.
Control Signals:
- /CS (Chip Select): Low to enable the device.
- /RAS (Row Address Strobe): Low to initiate a row access.
- /CAS (Column Address Strobe): Low to initiate a column access.
- /WE (Write Enable): Low to write data, high to read data.
- /DQM (Data Mask): Used to mask individual bytes during write operations.
Refresh:
- The device requires a refresh cycle every 64 ms.
- Use an auto-refresh command to perform the refresh operation.
Initialization:
- After power-up, the device must be initialized by issuing a precharge all banks command followed by a mode register set command.
Mode Register:
- The mode register can be programmed to set various operating modes such as burst length, burst type, and CAS latency.
Data Access:
- Data is valid after the specified access time (tAC) from the clock edge.
- Ensure that the data bus is not driven by external devices during read operations.
Temperature Considerations:
- Operate the device within the specified industrial temperature range (-40°C to +85°C).
- Store the device in the specified storage temperature range (-65°C to +150°C).
Power Management:
- Use the standby mode to reduce power consumption when the device is not in use.
- Ensure proper sequencing of power supply voltages during power-up and power-down.
By following these instructions, you can ensure reliable and efficient operation of the MT48LC32M16A2P-75C SDRAM.
(For reference only)View more about MT48LC32M16A2P-75C on main site