Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage (Vcc) | Operating supply voltage | 2.7 | - | 3.6 | V |
Standby Current | Supply current in standby mode | - | 10 | - | μA |
Active Current | Supply current during read or write operation | - | 50 | - | mA |
Access Time | Time from address valid to data valid | - | 70 | - | ns |
Write Cycle Time | Time required for a complete write cycle | - | 10 | - | ms |
Page Write Time | Time required to write a page | - | 5 | - | ms |
Sector Erase Time | Time required to erase a sector | - | 200 | - | ms |
Chip Erase Time | Time required to erase the entire chip | - | 5000 | - | ms |
Data Retention | Minimum guaranteed data retention time | - | - | 100 | years |
Operating Temperature | Range of operating temperatures | -40 | - | 85 | °C |
Storage Temperature | Range of storage temperatures | -65 | - | 150 | °C |
Instructions
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
- Connect the Vcc pin to the power source and GND pin to ground.
Pin Configuration:
- Refer to the datasheet for the specific pin configuration of the SST49LF080A-33-4C-NHE.
- Ensure all pins are correctly connected, especially Vcc, GND, and control signals (CE, OE, WE, etc.).
Read Operation:
- Set the Chip Enable (CE) and Output Enable (OE) to low.
- Apply the desired address to the address lines.
- Data will be available on the data lines after the access time (70ns).
Write Operation:
- Set the Chip Enable (CE) and Write Enable (WE) to low.
- Apply the desired address and data to the address and data lines.
- The write cycle time is 10ms.
Erase Operations:
- Sector Erase:
- Set the Chip Enable (CE) and Write Enable (WE) to low.
- Apply the sector address to the address lines.
- The sector erase time is 200ms.
- Chip Erase:
- Set the Chip Enable (CE) and Write Enable (WE) to low.
- Apply the chip erase command.
- The chip erase time is 5000ms.
- Sector Erase:
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 85°C.
- Store the device within the temperature range of -65°C to 150°C.
Data Retention:
- Data is guaranteed to be retained for at least 100 years under normal operating conditions.