Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage (LED) VF 1.2 1.4 1.6 V IF = 20 mA
Reverse Voltage (LED) VR -5 - -5 V IR ≤ 1 μA
Forward Current (LED) IF - 20 50 mA Continuous
Peak Forward Current (LED) IF(PK) - - 150 mA tP = 1 ms, Duty Cycle = 1%
Storage Temperature TSTG -40 - 125 °C -
Operating Temperature TA -40 - 85 °C -
Isolation Voltage VIORM - 5000 - Vrms 1 min, 50/60 Hz
Collector-Emitter Breakdown Voltage V(BR)CEO - - 70 V IC = 50 mA, TA = 25°C
Collector-Emitter Saturation Voltage VCE(SAT) 0.3 0.5 0.7 V IC = 100 mA, IF = 20 mA, TA = 25°C
Collector Current IC - 100 150 mA VCE = 5 V, IF = 20 mA
Turn-On Time ton - 1 3 μs VCC = 5 V, RL = 100 Ω, IF = 20 mA
Turn-Off Time toff - 1 3 μs VCC = 5 V, RL = 100 Ω, IF = 20 mA

Instructions for Using TLP550G:

  1. Power Supply:

    • Ensure that the supply voltage (VCC) is within the operating range of 4.5 V to 5.5 V.
    • Connect the power supply to the VCC and GND pins.
  2. Input Signal:

    • Apply the input signal to the LED (anode and cathode).
    • The forward current (IF) should be set to 20 mA for optimal performance.
    • Use a current-limiting resistor to prevent exceeding the maximum forward current of 50 mA.
  3. Output Signal:

    • Connect the load between the collector and the power supply.
    • The emitter should be connected to ground.
    • Ensure the load resistance (RL) is appropriate for the collector current (IC).
  4. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 85°C.
    • Avoid exceeding the storage temperature range of -40°C to 125°C.
  5. Isolation:

    • The device provides galvanic isolation up to 5000 Vrms for 1 minute at 50/60 Hz.
    • Ensure proper insulation and spacing to maintain this isolation.
  6. Timing:

    • The turn-on and turn-off times are typically 1 μs to 3 μs. Ensure that the circuit design accounts for these delays.
  7. Handling:

    • Handle the device with care to avoid damage.
    • Follow ESD (Electrostatic Discharge) precautions to prevent damage to the device.
  8. Mounting:

    • Mount the device on a PCB with proper thermal management if high power dissipation is expected.
    • Ensure good mechanical stability and avoid excessive mechanical stress on the leads.