BUY Z8018008PEC https://www.utsource.net/itm/p/5418232.html
ENHANCED Z180 MICROPROCESSOR
| Parameter | Description | Value |
|---|---|---|
| Part Number | Full part number | Z8018008PEC |
| Package Type | Type of package | 44-Pin PLCC |
| Operating Temperature | Operating temperature range | -40°C to +85°C |
| Supply Voltage (Vcc) | Supply voltage range | 3.0V to 5.5V |
| Clock Frequency | Maximum clock frequency | 27 MHz |
| I/O Structure | Input/output structure | CMOS |
| Program Memory | Size of program memory | 8K x 8 Flash ROM |
| Data Memory | Size of data memory | 384 x 8 RAM |
| EEPROM | Size of EEPROM | 64 x 8 EEPROM |
| Instruction Set | Type of instruction set | Z80 |
| Interrupts | Number of interrupt sources | 9 |
| Timers/Counters | Number and type of timers/counters | 3 x 16-bit Timer/Counter |
| Serial Communication | Serial communication interfaces | UART, SIO |
| Watchdog Timer | Availability of watchdog timer | Yes |
| Power Management | Power saving modes | Idle, Doze, Stop |
Instructions for Use:
Powering the Device:
- Ensure that the supply voltage (Vcc) is within the specified range of 3.0V to 5.5V.
- Connect Vss to ground and Vcc to the power supply.
Clock Configuration:
- The device supports a maximum clock frequency of 27 MHz. Use an external crystal or oscillator as needed.
Programming:
- Program the Flash ROM using standard programming tools compatible with Z80 architecture.
- Verify the code after programming to ensure accuracy.
Memory Access:
- Utilize the internal 8K x 8 Flash ROM for program storage and 384 x 8 RAM for data storage.
- Use the 64 x 8 EEPROM for non-volatile data storage.
Peripheral Setup:
- Configure the UART and SIO for serial communication as required by your application.
- Initialize the 3 x 16-bit Timer/Counters for timing functions.
Interrupt Handling:
- Implement interrupt service routines for up to 9 interrupt sources to handle real-time events.
Power Management:
- Use Idle, Doze, and Stop modes to manage power consumption effectively in battery-operated applications.
Testing:
- After setup, test all functionalities including timers, interrupts, and communication interfaces to ensure proper operation.
For detailed specifications and advanced features, refer to the official datasheet provided by the manufacturer.
(For reference only)View more about Z8018008PEC on main site