TOP262LN

TOP262LN

Category: IC Chips

Specifications
SKU
5773490
Details

BUY TOP262LN https://www.utsource.net/itm/p/5773490.html
Enhanced EcoSmart, Integrated Off-Line Switcher with Advanced Feature Set and Extended Power Range
Parameter Symbol Min Typ Max Unit Notes
Input Voltage VIN 180 - 375 VAC Operating range
Output Power POUT - 24 30 W Continuous output power
Switching Frequency fSW - 132 - kHz Typical operating frequency
Quiescent Current IQ - 1.5 - mA At no load
Efficiency (Typical) η - 85 - % At full load
Output Voltage Range VOUT 5 - 24 VDC Adjustable output voltage
Output Current IOUT - 1.25 2.5 A Maximum continuous current
Standby Power PSTBY - 0.5 - W In standby mode
Thermal Shutdown TSD - 160 - °C Junction temperature
Operating Temperature TOPR -40 - 125 °C Ambient temperature range
Storage Temperature TSTG -65 - 150 °C Storage temperature range
Humidity RH - 95 - % Non-condensing

Instructions for Using TOP262LN

  1. Input Voltage:

    • Ensure the input voltage is within the specified range (180VAC to 375VAC) to avoid damage to the device.
    • Use appropriate filtering and transient protection circuits to protect against voltage spikes.
  2. Output Configuration:

    • The output voltage can be adjusted using external components such as resistors. Refer to the datasheet for specific resistor values.
    • Ensure the output current does not exceed the maximum continuous current (2.5A) to prevent overheating and potential failure.
  3. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed 160°C. Use heatsinks or other cooling methods if necessary.
    • Operate the device within the specified ambient temperature range (-40°C to 125°C).
  4. Efficiency:

    • The typical efficiency is around 85% at full load. Optimize the design to minimize losses and improve overall efficiency.
  5. Standby Mode:

    • In standby mode, the device consumes approximately 0.5W. Use this feature to reduce power consumption when the device is not in use.
  6. Storage and Handling:

    • Store the device in a dry environment with humidity levels below 95% non-condensing.
    • Handle the device with care to avoid static discharge and physical damage.
  7. Safety Considerations:

    • Follow all safety guidelines and regulations when designing and handling high-voltage circuits.
    • Ensure proper insulation and isolation to prevent electrical shock.
  8. Testing and Validation:

    • Test the device under various operating conditions to ensure it meets the required performance specifications.
    • Validate the design with appropriate test equipment and procedures.
(For reference only)

View more about TOP262LN on main site