Details
BUY TOP262LN https://www.utsource.net/itm/p/5773490.html
Enhanced EcoSmart, Integrated Off-Line Switcher with Advanced Feature Set and Extended Power Range
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Input Voltage | VIN | 180 | - | 375 | VAC | Operating range |
Output Power | POUT | - | 24 | 30 | W | Continuous output power |
Switching Frequency | fSW | - | 132 | - | kHz | Typical operating frequency |
Quiescent Current | IQ | - | 1.5 | - | mA | At no load |
Efficiency (Typical) | η | - | 85 | - | % | At full load |
Output Voltage Range | VOUT | 5 | - | 24 | VDC | Adjustable output voltage |
Output Current | IOUT | - | 1.25 | 2.5 | A | Maximum continuous current |
Standby Power | PSTBY | - | 0.5 | - | W | In standby mode |
Thermal Shutdown | TSD | - | 160 | - | °C | Junction temperature |
Operating Temperature | TOPR | -40 | - | 125 | °C | Ambient temperature range |
Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Humidity | RH | - | 95 | - | % | Non-condensing |
Instructions for Using TOP262LN
Input Voltage:
- Ensure the input voltage is within the specified range (180VAC to 375VAC) to avoid damage to the device.
- Use appropriate filtering and transient protection circuits to protect against voltage spikes.
Output Configuration:
- The output voltage can be adjusted using external components such as resistors. Refer to the datasheet for specific resistor values.
- Ensure the output current does not exceed the maximum continuous current (2.5A) to prevent overheating and potential failure.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 160°C. Use heatsinks or other cooling methods if necessary.
- Operate the device within the specified ambient temperature range (-40°C to 125°C).
Efficiency:
- The typical efficiency is around 85% at full load. Optimize the design to minimize losses and improve overall efficiency.
Standby Mode:
- In standby mode, the device consumes approximately 0.5W. Use this feature to reduce power consumption when the device is not in use.
Storage and Handling:
- Store the device in a dry environment with humidity levels below 95% non-condensing.
- Handle the device with care to avoid static discharge and physical damage.
Safety Considerations:
- Follow all safety guidelines and regulations when designing and handling high-voltage circuits.
- Ensure proper insulation and isolation to prevent electrical shock.
Testing and Validation:
- Test the device under various operating conditions to ensure it meets the required performance specifications.
- Validate the design with appropriate test equipment and procedures.
View more about TOP262LN on main site