Details
BUY MN1381-S https://www.utsource.net/itm/p/6218498.html
DETECT IC CMOS 4.2V TO-92
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 2.7 | - | 5.5 | V |
| Output Current | IOUT | Continuous | - | 100 | - | mA |
| Quiescent Current | IQ | VDD = 5V | - | 1.5 | - | μA |
| Dropout Voltage | VDROPOUT | IOUT = 100mA | - | 0.3 | - | V |
| Load Regulation | ΔVL/ΔIL | IOUT = 10mA to 100mA | - | 0.05 | - | % |
| Line Regulation | ΔVL/ΔVI | VDD = 2.7V to 5.5V | - | 0.05 | - | % |
| Thermal Shutdown | TSD | Typical | - | 160 | - | °C |
| Short-Circuit Current | ISC | VDD = 5V | - | 200 | - | mA |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V.
- Use appropriate decoupling capacitors (typically 0.1μF and 10μF) close to the input and output pins to stabilize the power supply.
Output Current:
- The device can provide up to 100mA of continuous output current.
- For higher currents, consider using additional external components or a different regulator.
Quiescent Current:
- The quiescent current is typically 1.5μA at 5V supply voltage, ensuring low power consumption.
Dropout Voltage:
- The dropout voltage is typically 0.3V at 100mA output current, making it suitable for low-voltage applications.
Regulation:
- The load regulation is typically 0.05% over the output current range from 10mA to 100mA.
- The line regulation is also typically 0.05% over the input voltage range from 2.7V to 5.5V.
Thermal Protection:
- The device includes thermal shutdown protection, which activates at approximately 160°C to prevent damage from overheating.
Short-Circuit Protection:
- The short-circuit current is limited to typically 200mA to protect the device from damage during short circuits.
Layout Considerations:
- Place the MN1381-S as close as possible to the load to minimize trace resistance and inductance.
- Use wide and short traces for power and ground connections to reduce parasitic effects.
Storage and Handling:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage the internal components.