BTS133BKSA1

BTS133BKSA1


Specifications
SKU
7624465
Details

BUY BTS133BKSA1 https://www.utsource.net/itm/p/7624465.html
IC SWITCH LOSIDE PWR N-CH TO-220
Parameter Symbol Min Typ Max Unit Condition/Notes
Supply Voltage VCC -0.5 - 45 V Continuous operation
Input Voltage (High Level) VIH 2.5 - VCC V Control input high level voltage
Input Voltage (Low Level) VIL -0.5 - 0.8 V Control input low level voltage
Output Current (Continuous) IOUT(cont) - - 1.5 A At TA = 25°C, RDS(on) < 0.04 Ω
Output Current (Pulsed) IOUT(pulse) - - 6 A At TA = 25°C, tpulse ≤ 1 ms
Power Dissipation PD - - 35 W At TA = 25°C, with adequate heat sink
Junction Temperature TJ -40 - 150 °C Maximum operating temperature
Storage Temperature TSTG -40 - 150 °C Temperature range for storage

Instructions for Use:

  1. Supply Voltage (VCC):

    • Ensure the supply voltage is within the specified range of -0.5 V to 45 V to avoid damage to the device.
  2. Input Voltage (VIH and VIL):

    • The control input should be set to a high level (≥ 2.5 V) or low level (≤ 0.8 V) to ensure proper switching of the output.
    • Avoid intermediate voltages to prevent undefined states.
  3. Output Current:

    • The continuous output current should not exceed 1.5 A at ambient temperature (TA) of 25°C.
    • For pulsed applications, the peak current can reach up to 6 A, but the pulse duration must not exceed 1 ms.
  4. Power Dissipation (PD):

    • The maximum power dissipation is 35 W at 25°C ambient temperature. Use an appropriate heat sink to manage heat dissipation effectively.
  5. Temperature Considerations:

    • The junction temperature (TJ) should not exceed 150°C to prevent thermal damage.
    • Store the device in an environment where the temperature ranges from -40°C to 150°C.
  6. Heat Sinking:

    • For high-power applications, ensure that the device is properly heat-sunk to maintain safe operating temperatures.
  7. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal components.
    • Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
  8. Mounting:

    • Ensure that the device is mounted securely to prevent mechanical stress, which can affect performance and reliability.
  9. Testing:

    • Before final assembly, test the device under typical operating conditions to ensure it meets the required specifications.

By following these guidelines, you can ensure optimal performance and longevity of the BTS133BKSA1.