BUY ITS640S2SHKSA1 https://www.utsource.net/itm/p/7626984.html
IC SWITCH HISIDE SMART TO220-7
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | - | 28 | V | Operating input voltage range |
| Output Voltage | VOUT | - | 3.3 | - | V | Regulated output voltage |
| Continuous Current | IOUT | - | 2 | 3 | A | Continuous output current |
| Peak Current | IPEAK | - | - | 4 | A | Peak output current |
| Efficiency | η | - | 90 | - | % | Typical efficiency at nominal conditions |
| Switching Frequency | fSW | - | 1.2 | - | MHz | Switching frequency of the internal oscillator |
| Quiescent Current | IQ | - | 60 | - | μA | Quiescent current at no load |
| Dropout Voltage | VDROPOUT | - | 300 | - | mV | Dropout voltage at maximum load |
| Load Regulation | - | - | 0.5 | - | % | Change in output voltage over load range |
| Line Regulation | - | - | 0.2 | - | % | Change in output voltage over input voltage range |
| Start-up Time | tSTART | - | 500 | - | μs | Time to reach regulation from power-on |
| Short-Circuit Current | ISCC | - | - | 3.5 | A | Current limit during short-circuit |
| Thermal Shutdown | TSD | - | 160 | - | °C | Temperature at which thermal shutdown occurs |
Instructions for Use:
- Input Connection: Connect the input voltage (VIN) within the specified range of 4.5V to 28V.
- Output Configuration: Ensure the output voltage is set to 3.3V, suitable for most applications requiring a stable 3.3V supply.
- Current Handling: The device can handle continuous currents up to 3A and peak currents up to 4A. Design your system to stay within these limits.
- Efficiency Consideration: For optimal efficiency, operate under typical conditions where the efficiency is around 90%.
- Thermal Management: Monitor the operating temperature to prevent exceeding the thermal shutdown threshold of 160°C.
- Protection Features: The device includes short-circuit protection with a current limit of 3.5A and will shut down if it exceeds the thermal limit.
- Start-up Procedure: After applying power, allow approximately 500μs for the regulator to stabilize before connecting any loads.
Note: Always refer to the specific datasheet or application note provided by the manufacturer for detailed guidelines and additional parameters not listed here.
(For reference only)View more about ITS640S2SHKSA1 on main site