Details
BUY HX8005NLT https://www.utsource.net/itm/p/8646616.html
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 2.7 | - | 5.5 | V | - |
| Output Voltage | VOUT | 1.2 | - | 3.3 | V | Adjustable |
| Quiescent Current | IQ | - | 60 | - | μA | VIN = 5V, IOUT = 0mA |
| Dropout Voltage | VDROPOUT | - | 200 | - | mV | VIN = 3.3V, IOUT = 500mA |
| Load Regulation | - | - | 2 | - | % | VIN = 5V, IOUT = 0 to 500mA |
| Line Regulation | - | - | 0.1 | - | %/V | VIN = 4.5 to 5.5V, IOUT = 100mA |
| Output Current | IOUT | - | 500 | - | mA | - |
| Thermal Shutdown | TSD | - | 160 | - | °C | - |
| Short-Circuit Protection | SCP | - | - | - | - | Auto-restart |
Instructions for Use:
Input Voltage (VIN):
- Ensure the input voltage is within the range of 2.7V to 5.5V.
- Do not exceed the maximum input voltage to avoid damaging the regulator.
Output Voltage (VOUT):
- The output voltage can be adjusted between 1.2V and 3.3V.
- Use an external resistor network to set the desired output voltage.
Quiescent Current (IQ):
- The quiescent current is typically 60 μA when no load is applied.
- This value helps in power consumption calculations for low-power applications.
Dropout Voltage (VDROPOUT):
- The dropout voltage is typically 200 mV at a load current of 500 mA.
- Ensure that the input voltage is at least 200 mV higher than the desired output voltage to maintain regulation.
Load Regulation:
- The load regulation is typically 2% over the load range from 0 to 500 mA.
- This indicates the stability of the output voltage under varying load conditions.
Line Regulation:
- The line regulation is typically 0.1% per volt change in input voltage.
- This ensures minimal changes in output voltage due to variations in input voltage.
Output Current (IOUT):
- The maximum continuous output current is 500 mA.
- Do not exceed this limit to avoid overheating or damage.
Thermal Shutdown (TSD):
- The device will shut down if the internal temperature exceeds approximately 160°C.
- This feature protects the regulator from overheating and potential damage.
Short-Circuit Protection (SCP):
- The regulator has built-in short-circuit protection with auto-restart functionality.
- In case of a short circuit, the regulator will cycle on and off until the short is removed.
Additional Notes:
- PCB Layout: Ensure proper heat dissipation by using a large copper area around the regulator.
- Capacitors: Use appropriate input and output capacitors to stabilize the regulator and reduce noise.
- Resistor Network: For adjustable output voltage, use a resistor network connected to the ADJ pin. Refer to the datasheet for specific resistor values.
View more about HX8005NLT on main site