Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Drain-Source On-Resistance | Rds(on) | - | 1.2 | - | Ω | @ Vgs=10V, Id=5A |
Gate Charge | Qg | - | 74 | - | nC | Total gate charge |
Input Capacitance | Ciss | - | 2000 | - | pF | @ Vds=400V |
Output Capacitance | Coss | - | 600 | - | pF | @ Vds=400V |
Reverse Transfer Capacitance | Crss | - | 450 | - | pF | @ Vds=400V |
Threshold Voltage | Vth | 2 | 4 | 6 | V | Gate threshold voltage |
Continuous Drain Current | Id | - | - | 20 | A | @ Tc=25°C |
Pulse Drain Current | Idm | - | - | 200 | A | @ Tj=25°C, t=10μs |
Drain-Source Breakdown Voltage | Vds(br) | 600 | - | - | V | @ Id=250μA, Tj=25°C |
Power Dissipation | Ptot | - | - | 230 | W | @ Ta=25°C, θja=0.89°C/W |
Junction Temperature | Tj | -55 | - | 150 | °C | Operating temperature range |
Storage Temperature | Tstg | -55 | - | 150 | °C | Storage temperature range |
Instructions for SPW20N60C3:
Mounting and Handling:
- Ensure the device is mounted on a suitable heatsink to manage thermal resistance effectively.
- Handle with care to avoid damage to the pins or body.
Biasing and Operation:
- Apply gate-source voltage (Vgs) within the specified limits to control the drain current (Id).
- Ensure that the operating conditions do not exceed the maximum ratings for continuous drain current and drain-source voltage.
Thermal Management:
- Monitor junction temperature to ensure it remains within the operational range (-55°C to 150°C).
- Use appropriate cooling methods such as forced air or liquid cooling if necessary.
Storage:
- Store in a dry environment within the storage temperature range (-55°C to 150°C).
Electrical Connections:
- Verify all connections are secure and insulated properly to prevent short circuits.
- Follow proper PCB layout guidelines to minimize parasitic inductances and capacitances.
Testing:
- Perform initial testing at low power levels to verify correct operation before full-power testing.
- Regularly inspect the device for signs of wear or damage during prolonged use.
Safety Precautions:
- Always use protective equipment when handling high-voltage components.
- Be aware of potential risks associated with high currents and voltages.
View more about SPW20N60C3 20N60C3 TO-247 20A600V on main site