Details

BUY ACPL-330J-500E https://www.utsource.net/itm/p/8647558.html

Parameter Symbol Min Typ Max Unit Description
Input Forward Voltage VF 1.0 1.2 1.4 V Forward voltage at IF = 20 mA
Input Current IF - 20 - mA Forward current at VF = 1.2 V
CTR (Current Transfer Ratio) CTR 50 150 300 % Current transfer ratio at IF = 20 mA, VCE = 5V
Output Saturation Voltage VCESAT - 0.2 0.3 V Collector-emitter saturation voltage
Isolation Voltage VIORM - - 5000 Vrms Maximum repetitive peak isolation voltage
Operating Temperature Topr -40 - 85 掳C Operating temperature range
Storage Temperature Tstg -40 - 100 掳C Storage temperature range

Instructions for ACPL-330J-500E

  1. Power Supply: Ensure that the input voltage is within the specified limits to avoid damage to the device.
  2. Current Limitation: Do not exceed the maximum forward current (IF) rating of 20 mA to prevent overheating or failure.
  3. Isolation Considerations: The device provides a high isolation voltage up to 5000 Vrms, suitable for applications requiring electrical isolation.
  4. Temperature Management: Operate within the specified operating temperature range (-40掳C to 85掳C). For extended storage, ensure temperatures do not exceed -40掳C to 100掳C.
  5. CTR Utilization: Use the CTR value to design circuits ensuring efficient current transfer from input to output. Adjust the input current based on the CTR to achieve desired output performance.
  6. Saturation Voltage Monitoring: Monitor the output saturation voltage (VCESAT) to ensure it remains within acceptable limits for optimal performance.
  7. Handling Precautions: Handle with care to avoid static discharge and physical damage. Follow standard ESD protection guidelines during installation and handling.
(For reference only)

View more about ACPL-330J-500E on main site