ACPL-330J-500E
Specifications
Details
BUY ACPL-330J-500E https://www.utsource.net/itm/p/8647558.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Forward Voltage | VF | 1.0 | 1.2 | 1.4 | V | Forward voltage at IF = 20 mA |
| Input Current | IF | - | 20 | - | mA | Forward current at VF = 1.2 V |
| CTR (Current Transfer Ratio) | CTR | 50 | 150 | 300 | % | Current transfer ratio at IF = 20 mA, VCE = 5V |
| Output Saturation Voltage | VCESAT | - | 0.2 | 0.3 | V | Collector-emitter saturation voltage |
| Isolation Voltage | VIORM | - | - | 5000 | Vrms | Maximum repetitive peak isolation voltage |
| Operating Temperature | Topr | -40 | - | 85 | 掳C | Operating temperature range |
| Storage Temperature | Tstg | -40 | - | 100 | 掳C | Storage temperature range |
Instructions for ACPL-330J-500E
- Power Supply: Ensure that the input voltage is within the specified limits to avoid damage to the device.
- Current Limitation: Do not exceed the maximum forward current (IF) rating of 20 mA to prevent overheating or failure.
- Isolation Considerations: The device provides a high isolation voltage up to 5000 Vrms, suitable for applications requiring electrical isolation.
- Temperature Management: Operate within the specified operating temperature range (-40掳C to 85掳C). For extended storage, ensure temperatures do not exceed -40掳C to 100掳C.
- CTR Utilization: Use the CTR value to design circuits ensuring efficient current transfer from input to output. Adjust the input current based on the CTR to achieve desired output performance.
- Saturation Voltage Monitoring: Monitor the output saturation voltage (VCESAT) to ensure it remains within acceptable limits for optimal performance.
- Handling Precautions: Handle with care to avoid static discharge and physical damage. Follow standard ESD protection guidelines during installation and handling.