| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Input Forward Voltage | VF | - | 1.2 | 1.6 | V | IF = 20 mA, TA = 25掳C |
| Peak Reverse Voltage | VR | - | - | 5 | V | |
| Continuous Reverse Current | IR | - | - | 10 | 渭A | VR = 5 V, TA = 25掳C |
| Output Collector-Emitter Voltage | V<subCEO | - | - | 70 | V | IC = 0.1 mA, TA = 25掳C |
| Output Collector Current | IC | - | - | 100 | mA | VCEO = 70 V, TA = 25掳C |
| Isolation Voltage | VIORM | - | - | 500 | V | 1 minute, 50/60 Hz |
| CTR (Current Transfer Ratio) | CTR | 100 | 200 | 400 | % | IF = 5 mA, IC = 5 mA, TA = 25掳C |
| Propagation Delay Time | tPLH, tPHL | - | 2.5 | 4.5 | 渭s | IF = 20 mA, IC = 10 mA, TA = 25掳C |
| Storage Temperature Range | TSTG | -40 | - | 125 | 掳C | |
| Operating Temperature Range | TA | -40 | - | 105 | 掳C |
Instructions for Use:
Power Supply:
- Ensure that the input forward voltage (VF) is within the specified range to avoid damage to the device.
- The output collector-emitter voltage (V<subCEO) should not exceed 70 V to prevent breakdown.
Current Handling:
- The input forward current (IF) should be set to 20 mA for optimal performance.
- The output collector current (IC) should not exceed 100 mA to ensure reliable operation.
Isolation:
- The isolation voltage (VIORM) is rated at 500 V. Ensure that the device is used in circuits where this isolation is necessary to protect against high voltages.
Temperature Considerations:
- The device can operate over a wide temperature range from -40掳C to 105掳C. However, for best performance, keep the operating temperature within this range.
- Store the device in an environment with temperatures between -40掳C and 125掳C.
Timing Parameters:
- The propagation delay time (tPLH, tPHL) is crucial for timing-sensitive applications. Ensure that the delay times are within the specified range to avoid timing issues.
Mounting and Handling:
- Handle the device with care to avoid mechanical stress.
- Follow proper soldering techniques to ensure reliable connections and prevent thermal damage.
Testing:
- Before using the device in a final application, test it under the expected operating conditions to verify performance and reliability.
Compliance:
- Ensure that the device meets all relevant safety and compliance standards for your specific application.
View more about HCPL-3120V-500E on main site