Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Blocking Voltage | V_BR | - | - | 1200 | V | |
Continuous Current | I_C | - | - | 100 | A | |
Peak Current | I_FM | - | - | 200 | A | |
Power Dissipation | P_T | - | - | 1500 | W | |
Junction Temperature | T_J | -25 | - | 175 | °C | |
Storage Temperature | T_STG | -55 | - | 150 | °C | |
Thermal Resistance | R_TH | - | 0.8 | - | K/W | |
Gate Charge | Q_G | - | 120 | - | nC | |
Input Capacitance | C_ISS | - | 3500 | - | pF | |
Output Capacitance | C_OSS | - | 1000 | - | pF | |
Reverse Transfer Capacit. | C_RSS | - | 2500 | - | pF | |
Turn-On Time | t_on | - | 50 | - | ns | |
Turn-Off Time | t_off | - | 70 | - | ns | |
Switching Loss | E_SW | - | 1.5 | - | mJ |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain junction temperature within specified limits.
- Use recommended mounting torque for screws to avoid damage.
Operation:
- Do not exceed the maximum blocking voltage (V_BR) of 1200V.
- Continuous current (I_C) should not exceed 100A.
- Peak current (I_FM) should be limited to 200A to prevent overheating.
Thermal Management:
- Monitor junction temperature (T_J) to ensure it does not exceed 175°C.
- Use thermal paste or other thermal interface materials to improve heat transfer.
Electrical Connections:
- Ensure all connections are secure and free from corrosion.
- Use appropriate wire gauges to handle the rated currents.
Storage:
- Store the device in a dry, cool place with temperatures between -55°C and 150°C.
- Avoid exposure to high humidity and corrosive environments.
Handling:
- Handle with care to avoid mechanical stress on the package.
- Use ESD protection when handling to prevent damage from static electricity.
Testing:
- Perform initial testing under controlled conditions to verify performance parameters.
- Regularly inspect the device for signs of wear or damage.
Documentation:
- Refer to the datasheet for detailed specifications and application notes.
- Contact the manufacturer for technical support if needed.
View more about 6MBI100U4B-120-01 on main site