Details
BUY 6MBP50VAA060-50 https://www.utsource.net/itm/p/8799558.html
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Breakdown Voltage | V(BR)DSS | - | 600 | - | V | |
Forward Voltage | VF | - | 1.8 | - | V | @ IF = 5 A |
Reverse Recovery Time | trr | - | 45 | - | ns | @ IF = 5 A, dIT/dt = 100 A/μs |
Junction Capacitance | CJ0 | - | 200 | - | pF | @ VDS = 0 V, f = 1 MHz |
Gate Charge | QG | - | 90 | - | nC | |
Total Power Dissipation | PD | - | 100 | - | W | @ TC = 25°C |
Operating Junction Temperature | TJ | -55 | - | 175 | °C |
Instructions for Use:
Handling Precautions:
- Ensure proper ESD protection during handling.
- Avoid exceeding the maximum junction temperature to prevent damage.
Mounting:
- Use appropriate mounting hardware to ensure good thermal contact with the heatsink.
- Follow manufacturer guidelines for torque specifications on screws.
Electrical Connections:
- Verify all electrical connections are secure and correctly oriented.
- Use insulated tools to avoid short circuits.
Thermal Management:
- Ensure adequate cooling is provided to keep the device within its operating temperature range.
- Regularly inspect the heatsink and cooling system for proper function.
Testing:
- Perform initial testing at low power levels to verify correct operation.
- Gradually increase power while monitoring temperature and performance.
Storage:
- Store in a dry, cool environment away from direct sunlight.
- Keep components in original packaging until ready for use.
View more about 6MBP50VAA060-50 on main site